Fabrication and Evaluation of Organic Field-Effect Transistors (OFETs) : anti-DMADT

anti-DMADT [D4617]

2,8-Dimethylanthra[2,3-b:6,7-b']dithiophene (purified by sublimation)
anti-DMADT
CAS RN: 1019983-99-3
Product Number: D4617

Performance of anti-DMADT [D4617]-based OFETs

Fabrication method and evaluation of vacuum-deposited anti-DMADT [D4617]



Table. OFETs Characteristics of anti-DMADT [D4617]

Entry Fabrication Method Device Configuration SAM Treatment Tsub (°C) Annealing Temp.a (°C) Polarity μ (cm2 V−1 s−1) Vth (V) Ion/Ioff
Entry1 Fabrication MethodVacuum
deposition
Device ConfigurationTCBG SAM Treatmentw/o
Bare
Tsub (°C)RT Annealing Temp.a (°C)w/o Polarityp μ (cm2 V−1 s−1)0.11 Vth (V)‒14 Ion/Ioff104
Entry2 Fabrication MethodVacuum
deposition
Device ConfigurationTCBG SAM Treatmentw/o
Bare
Tsub (°C)RT Annealing Temp.a (°C)120 Polarityp μ (cm2 V−1 s−1)0.11 Vth (V)‒7.7 Ion/Ioff104
aPost-annealing temperature.

Figure. Transfer curves in the saturated region

Figure. Transfer curves in the saturated region


Experimental details

Fabrication and evaluation of spin-coated anti-DMADT [D4617]-based OFETs

< Substrate>
  • Bare Si/SiO2 (thickness of SiO2: 200 nm)
< Vacuum Deposition>
  • Deposition rate of anti-DMADT [D4617] 0.3 Å/s (under a pressure of∼10−4 Pa)
  • Substrate temperature during deposition: RT
  • Deposition rate of Au: 1.0 Å/s (under a pressure of∼10−4 Pa)
< Post-Annealing Treatment>
  • Annealing condition: 120 ºC, 5 min, N2
< Device Configuration>
  • [n+-Si/SiO2 (200 nm) / anti-DMADT [D4617] (60 nm) / Au (40 nm)]
  • Top-Contact Bottom-Gate Type (TCBG)
  • Channel Length: 50 μm
  • Channel width: 1.5 mm
< Evaluation Condition>
  • Under N2
  • Field-effect mobilities (μ) were determined from the transfer curves in the saturation regime using the following equation: ID = (W/2L) μ Ci (VGVth)2
Session Status
Your session will timeout in 10 minutes. You will be redirected to the HOME page after session timeout. Please click the button to continue session from the same page. minute. You will be redirected to the HOME page after session timeout. Please click the button to continue session from the same page.