Maximum quantity allowed is 999
Please select the quantity
CAS RN: 143112-51-0 | Product Number: A5563
(R)-(-)-NBD-APy [=(R)-(-)-4-Nitro-7-(3-aminopyrrolidin-1-yl)-2,1,3-benzoxadiazole] [HPLC Labeling Reagent for e.e. Determination]
Purity: >98.0%(HPLC)
Synonyms:
- (R)-(-)-4-Nitro-7-(3-aminopyrrolidin-1-yl)benzofurazan
- (R)-(-)-4-Nitro-7-(3-aminopyrrolidin-1-yl)-2,1,3-benzoxadiazole
Product Documents:
Size | Unit Price | Same Day | 2-3 Business Days | Other Lead Time | Shipping Information |
---|---|---|---|---|---|
100MG |
$239.00
|
1 | 34 | Contact Us |
* Please contact our distributors or
TCI
to order our products. The above prices do not include freight cost, customs, and other charges to the destination.
* The storage conditions are subject to change without notice.
Product Number | A5563 |
Purity / Analysis Method | >98.0%(HPLC) |
Molecular Formula / Molecular Weight | C__1__0H__1__1N__5O__3 = 249.23 |
Physical State (20 deg.C) | Solid |
Storage Temperature | Room Temperature (Recommended in a cool and dark place, <15°C) |
Packaging and Container | 100MG-Glass Bottle with Plastic Insert (View image) |
CAS RN | 143112-51-0 |
PubChem Substance ID | 87563180 |
MDL Number | MFCD00191510 |
Specifications
Appearance | Orange to Brown to Dark red powder to crystal |
Purity(HPLC) | min. 98.0 area% |
Optical purity(LC) | min. 99.0 ee% |
Effect test of HPLC derivatization | Effective as labeling agent fo Ibuprofen |
NMR | confirm to structure |
Properties (reference)
Specific Rotation | -13° (C=0.2,CH3CN) |
GHS
Pictogram | |
Signal Word | Warning |
Hazard Statements | H315 : Causes skin irritation. H319 : Causes serious eye irritation. |
Precautionary Statements | P264 : Wash skin thoroughly after handling. P280 : Wear protective gloves/ eye protection/ face protection. P302 + P352 : IF ON SKIN: Wash with plenty of water. P337 + P313 : If eye irritation persists: Get medical advice/ attention. P305 + P351 + P338 : IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. P362 + P364 : Take off contaminated clothing and wash it before reuse. P332 + P313 : If skin irritation occurs: Get medical advice/ attention. |
Related Laws:
Transport Information:
H.S.code* | 2934.99-000 |
Application
HPLC Labeling Reagent for Chiral Carboxylic Acids
The compound 1 is an optically active HPLC fluorescence labeling reagent, which has a 2,1,3-benzoxadiazole skeleton and an amino group, and is used for optical purity determination of carboxylic acids. Labeling of racemic carboxylic acids can be done by using a mild condition such as the Mukaiyama-Corey method, and produces diastereomers without inducing racemization. These diastereomers can be separated by reversed phase HPLC, and an excellent chromatogram can be obtained by fluorescence detection at the excitation and emission wavelengths of 470 nm and 540 nm, respectively. Since their excitation and fluorescence wavelengths are at longer wavelengths, detection has less interference by contaminants. A highly sensitive detection can be done by using laser induced fluorescence detector.
Application example:2)
Add 0.1 mL of 10 mM labeling reagent 1 / acetonitrile solution, 0.25 mL of 2 µM carboxylic acid / acetonitrile solution, and 0.15 mL of 10 mM 2,2’-dipyridyl disulfide-triphenylphosphine / acetonitrile solution to a vessel, and react the mixture at room temperature for 4 h. Use the resultant as an HPLC sample solution.
For example, the detection limit (S/N=2) for naproxen is 15 fmol.
Add 0.1 mL of 10 mM labeling reagent 1 / acetonitrile solution, 0.25 mL of 2 µM carboxylic acid / acetonitrile solution, and 0.15 mL of 10 mM 2,2’-dipyridyl disulfide-triphenylphosphine / acetonitrile solution to a vessel, and react the mixture at room temperature for 4 h. Use the resultant as an HPLC sample solution.
For example, the detection limit (S/N=2) for naproxen is 15 fmol.
TCI Products Pamphlet
HPLC Labeling Reagents ( PDF 10MB )
HPLC Labeling Reagents ( PDF 10MB )
References
- 1)T. Toyo'oka, M. Ishibashi, T. Terao, Analyst 1992, 117, 727.
- 2)T. Toyo'oka, M. Ishibashi, T. Terao, J. Chromatogr. 1992, 625, 357.
PubMed Literature
Articles/Brochures
TCIMAIL
Product Documents (Note: Some products will not have analytical charts available.)
Safety Data Sheet (SDS)
Please select Language.
The requested SDS is not available.
Please Contact Us for more information.
Specifications
C of A & Other Certificates
Please enter Lot Number
Incorrect Lot Number. Please input only the 4-5 alphanumeric characters before the hyphen.
Sample C of A
This is a sample C of A and may not represent a recently manufactured lot of the product.
A sample C of A for this product is not available at this time.
Analytical Charts
Please enter Lot Number
Incorrect Lot Number. Please input only the 4-5 alphanumeric characters before the hyphen.
The requested analytical chart is not available. Sorry for the inconvenience.