Maximum quantity allowed is 999
请选择数量
CAS RN: 29270-56-2 | 产品编码: A5593
NBD-F (=4-Fluoro-7-nitro-2,1,3-benzoxadiazole) [for HPLC Labeling]
规格 | 单价 | 同一天 | 2-3个工作日 | 数量 |
---|---|---|---|---|
100MG |
S$261.00
|
≥100 | 20 |
|
产品编码 | A5593 |
纯度/分析方法 | >99.0%(HPLC) |
分子式/分子量 | C__6H__2FN__3O__3 = 183.10 |
外观与形状(20°C) | 固体 |
储存温度 | 冷冻 (<0°C) |
储存在惰性气体下 | 存放于惰性气体之中 |
应避免的情况 | 空气,加热 |
包装和容器 | 100MG-Glass Bottle with Plastic Insert (查看图片) |
CAS RN | 29270-56-2 |
Reaxys-RN | 1077571 |
PubChem物质ID | 87563200 |
SDBS (AIST Spectral DB) | 50330 |
MDL编号 | MFCD00010196 |
技术规格
Appearance | White to Yellow to Green powder to crystal |
Purity(HPLC) | min. 99.0 area% |
Effect test of HPLC derivatization | Effective as labeling agent for L-Isoleucine |
物性(参考值)
熔点 | 55 °C |
溶解性(可溶于) | 氯仿 |
GHS
象形图 | |
信号词 | Warning |
危险性说明 | H315 : Causes skin irritation. H319 : Causes serious eye irritation. |
防范说明 | P264 : Wash skin thoroughly after handling. P280 : Wear protective gloves/ eye protection/ face protection. P302 + P352 : IF ON SKIN: Wash with plenty of water. P337 + P313 : If eye irritation persists: Get medical advice/ attention. P305 + P351 + P338 : IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. P362 + P364 : Take off contaminated clothing and wash it before reuse. P332 + P313 : If skin irritation occurs: Get medical advice/ attention. |
相关法规
运输信息
HS编码* | 2934.99-000 |
应用
HPLC Labeling Reagent for Amines and Thiols
The compound 1 which is an HPLC fluorescence labeling reagent having a 2,1,3-benzoxadiazole skeleton, can easily react with amino or mercapto groups to form the corresponding derivatives. 1 itself does not fluoresce, and its ethanol solution is relatively stable for a week in a refrigerator. The derivatives can reach the detector without any decomposition under reversed phase HPLC. An excellent chromatogram can be obtained by fluorescence detection at the excitation and emission wavelengths of 470 nm and 530 nm, respectively. Since their excitation and fluorescence wavelengths are at longer wavelengths, detection has less interference by contaminants. Thus, further highly sensitive detection can be done by using laser induced fluorescence detector. When the reagent is hydrolyzed (NBD-OH), its fluorescence can be erased under an acidic condition. Therefore, this hydrolyzed reagent can be used as a post column reaction reagent5,7).
Application example:
[Amino acids] 2,3)
To 10 µL of 50 µM amino acid standard solution, add 10 µL of 0.1 M boric acid buffer solution (pH 8.0) and 20 µL of 50 mM labeling reagent 1 in ethanol solution, and incubate the mixture at 60 °C for 1 min. Immediately cool it with ice bath, and add 460 µL of 5 mM HCl to the reactant solution. Use 10 µL of the solution as an HPLC sample.
[Amino acids] 2,3)
To 10 µL of 50 µM amino acid standard solution, add 10 µL of 0.1 M boric acid buffer solution (pH 8.0) and 20 µL of 50 mM labeling reagent 1 in ethanol solution, and incubate the mixture at 60 °C for 1 min. Immediately cool it with ice bath, and add 460 µL of 5 mM HCl to the reactant solution. Use 10 µL of the solution as an HPLC sample.
TCI Products Pamphlet
HPLC Labeling Reagents ( PDF 10MB )
HPLC Labeling Reagents ( PDF 10MB )
References
- 1)K. Imai, Y. Watanabe, Anal. Chim. Acta 1981, 130, 377.
- 2)Y. Watanabe, K. Imai, Anal. Biochem. 1981, 116, 471.
- 3)Y. Watanabe, K. Imai, J. Chromatogr. 1982, 239, 723.
- 4)T. Toyo’oka, Y. Watanabe, K. Imai, Anal. Chim. Acta 1983, 149, 305.
- 5)Y. Watanabe, K. Imai, Anal. Chem. 1983, 55, 1786.
- 6)Y. Watanabe, K. Imai, J. Chromatogr. 1984, 309, 279.
- 7)H. Miyano, T. Toyo’oka, K. Imai, Anal. Chim. Acta 1985, 170, 81.
- 8)H. Kotaniguchi, M. Kawakatsu, T. Toyo’oka, K. Imai, J. Chromatogr. 1987, 420, 141.
参考文献
TCIMail
产品文档 (部分产品的分析图谱无法提供,敬请谅解。)
化学品安全说明书(SDS)
请选择语言。
如需更多帮助,请联系我 们。
技术规格
CoA及其他文档
请输入批号
批号输入有误。请输入中横线前的4-5个字母数字字符。
示例 CoA
可下载CoA示例。注:该示例不一定是最新批次的CoA。
目前没有该产品的 CoA 示例。
分析图谱
请输入批号
批号输入有误。请输入中横线前的4-5个字母数字字符。
很抱歉,您搜索的分析图谱无法提供。