Maximum quantity allowed is 999
请选择数量
CAS RN: 24463-19-2 | 产品编码: A5502
9-Chloromethylanthracene [for HPLC Labeling]
规格 | 单价 | 同一天 | 2-3个工作日 | 数量 |
---|---|---|---|---|
1G |
S$66.00
|
17 | 2 |
|
5G |
S$192.00
|
≥60 | 2 |
|
技术规格
Appearance | Light yellow to Yellow to Orange powder to crystal |
Purity(HPLC) | min. 95.0 area% |
Purity(Argentometric Titration) | min. 97.0 % |
Melting point | 138.0 to 142.0 °C |
NMR | confirm to structure |
物性(参考值)
熔点 | 140 °C |
GHS
象形图 | |
信号词 | Danger |
危险性说明 | H314 : Causes severe skin burns and eye damage. H290 : May be corrosive to metals. |
防范说明 | P501 : Dispose of contents/ container to an approved waste disposal plant. P260 : Do not breathe dusts or mists. P234 : Keep only in original container. P264 : Wash skin thoroughly after handling. P280 : Wear protective gloves/ protective clothing/ eye protection/ face protection. P390 : Absorb spillage to prevent material damage. P303 + P361 + P353 : IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water/shower. P301 + P330 + P331 : IF SWALLOWED: Rinse mouth. Do NOT induce vomiting. P363 : Wash contaminated clothing before reuse. P304 + P340 + P310 : IF INHALED: Remove person to fresh air and keep comfortable for breathing. Immediately call a POISON CENTER/doctor. P305 + P351 + P338 + P310 : IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Immediately call a POISON CENTER/doctor. P406 : Store in corrosive resistant container with a resistant inner liner. P405 : Store locked up. |
相关法规
RTECS# | CA9600000 |
运输信息
UN编号 | UN3261 |
类别 | 8 |
包装类别 | II |
HS编码* | 2903.99-000 |
应用
HPLC Labeling Reagent for Carboxylic Acids
The compound 1, an HPLC labeling reagent which has a chloromethyl group, easily reacts with a carboxyl group to form the corresponding ester in the presence of a base. The resultant ester is stable and can reach the detector without any decomposition under reversed phase HPLC. An excellent chromatogram can be obtained by measuring at 254 nm, an absorption wavelength that is generally used for UV detection. Furthermore, it has a characteristic fluorescence based on an anthracene skeleton, thus carboxylic acids can be detected with the detection limit of 2 fmol by fluorescence detection analysis at the excitation and emission wavelengths of 365 nm and 412 nm, respectively.
Application examples:
[Fatty acids]1)
Dissolve 60 µg of a sample in 1 mL of DMF, and add 1 mL of tetramethylammonium hydroxide / DMF solution (1 x 10-3 M) and 1 mL of the labeling reagent 1 / cyclohexane solution (5 x 10-3 M). Close the cap of the reaction vessel and incubate the solution at 75 °C for 30 min. Cool the resultant solution to room temperature and use it as an HPLC sample.
The detection limit = 0.1 pmol (UV detection: 254 nm)
The detection limit = 2 fmol (Fluorescence detection: λex 365 nm, λem 412 nm)
[Fatty acids]1)
Dissolve 60 µg of a sample in 1 mL of DMF, and add 1 mL of tetramethylammonium hydroxide / DMF solution (1 x 10-3 M) and 1 mL of the labeling reagent 1 / cyclohexane solution (5 x 10-3 M). Close the cap of the reaction vessel and incubate the solution at 75 °C for 30 min. Cool the resultant solution to room temperature and use it as an HPLC sample.
The detection limit = 0.1 pmol (UV detection: 254 nm)
The detection limit = 2 fmol (Fluorescence detection: λex 365 nm, λem 412 nm)
TCI Products Pamphlet
HPLC Labeling Reagents ( PDF 10MB )
HPLC Labeling Reagents ( PDF 10MB )
References
参考文献
文章/手册
TCIMail
产品文档 (部分产品的分析图谱无法提供,敬请谅解。)
化学品安全说明书(SDS)
请选择语言。
如需更多帮助,请联系我 们。
技术规格
CoA及其他文档
请输入批号
批号输入有误。请输入中横线前的4-5个字母数字字符。
示例 CoA
可下载CoA示例。注:该示例不一定是最新批次的CoA。
目前没有该产品的 CoA 示例。
分析图谱
请输入批号
批号输入有误。请输入中横线前的4-5个字母数字字符。
很抱歉,您搜索的分析图谱无法提供。