Maximum quantity allowed is 999
CAS RN: 3240-34-4 | 제품번호: I0330
Iodobenzene Diacetate
•본건의 원가격은 한국 대리점의 예상 판매가격입니다.자세한 정보가 필요하시면 연락해 주십시오.( SEJIN CI Co., Ltd. (한국총대리점) 전화 : 02-2655-2480 이메일 : sales@sejinci.co.kr)
•보관 조건은 예고없이 변경 될 수 있습니다. 제품 보관 조건의 최신 자료는 홈페이지에 기재되어 있으니 양해 부탁드립니다.
제품번호 | I0330 |
Purity/Analysis Method | >97.0%(T) |
M.F. / M.W. | C__1__0H__1__1IO__4 = 322.10 |
물리적 상태 (20 ℃) | Solid |
보관 조건 | Room Temperature (Recommended in a cool and dark place, <15°C) |
불활성 가스 하에서 보관 | Store under inert gas |
피해야 할 조건 | Moisture Sensitive |
CAS RN | 3240-34-4 |
Reaxys-RN | 1879369 |
PubChem Substance ID | 87571686 |
SDBS | 12662 |
MDL 번호 | MFCD00008692 |
Appearance | White to Light yellow powder to crystal |
Purity(Iodometric Titration) | min. 97.0 % |
Solubility in Methanol | almost transparency |
mp | 158 °C(dec.) |
Solubility in water | Insoluble |
용해성 (용해) | Methanol |
용해도 (불용성) | Ether |
픽토그램 | |
신호 워드 | Warning |
위험물 및 유해 등록 | H315 : Causes skin irritation. H319 : Causes serious eye irritation. |
주의 사항 | P264 : Wash skin thoroughly after handling. P280 : Wear protective gloves/ eye protection/ face protection. P302 + P352 : IF ON SKIN: Wash with plenty of water. P337 + P313 : If eye irritation persists: Get medical advice/ attention. P305 + P351 + P338 : IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. P362 + P364 : Take off contaminated clothing and wash it before reuse. P332 + P313 : If skin irritation occurs: Get medical advice/ attention. |
RTECS # | DA3525000 |
HS 번호* | 2931.90-000 |
-
Used Chemicals
-
Procedure
-
To a solution of 1-naphthalenemethanol (306 mg, 2.0 mmol) in dichloromethane (2 mL, 1.0 mol/L) was added TEMPO (31.2 mg, 0.20 mmol), PhI(OAc)2 (709mg, 2.2 mmol) and the mixture was stirred at room temperature for 4 hours. Dichloromethane (12.5 mL), saturated aqueous sodium thiosulfate solution (12.5 mL) was added and the mixture was stirred for 30 minutes. The organic layer was washed with saturated aqueous sodium bicarbonate solution (10 mL), brine (10 mL) and the organic layer was dried over sodium sulfate and filtered. The solvent was removed under reduced pressure and the residue was purified by column chromatography (ethyl acetate:hexane = 0:100 - 3:97 on silica gel) to give 1-naphthaldehyde as a yellow liquid (291 mg, 93%).
-
Experimenter’s Comments
-
The reaction mixture was monitored by TLC (ethyl acetate:hexane = 1:9, Rf = 0.50).
-
Analytical Data
-
1-Naphthaldehyde
1H NMR (400 MHz, CDCl3); δ 10.41 (s, 1H), 9.26 (d, J = 8.9 Hz, 1H), 8.11 (d, J = 8.4 Hz, 1H), 8.01 (d, J = 6.8 Hz, 1H), 7.93 (d, J = 8.9 Hz, 1H), 7.74-7.57 (m, 3H).
-
Lead Reference
-
- 2-(Hydroxyimino)aldehydes: Photo- and Physicochemical Properties of a Versatile Functional Group for Monomer Design
-
Used Chemicals
-
Procedure
-
To a solution of 2-phenylimidazoline (500 mg, 3.4 mmol), potassium carbonate (520 mg, 3.8 mmol, 1.1 equiv) in DMSO (17 mL) was added iodobenzene diacetate (1.21 g, 3.8 mmol, 1.1 equiv) and stirred at rt for 18 hours. The residue was diluted with ethyl acetate (75 mL) and washed with saturated aqueous sodium bicarbonate solution (50 mL, twice) dried over sodium sulfate and filtered. The solvent was removed under reduced pressure and the residue was purified by column chromatography (on aminosilica gel, ethyl acetate:hexane = 0:1 - 1:0), giving 2-phenylimidazole as a white solid (340 mg,y. 69%).
-
Experimenter’s Comments
-
The reaction mixture was monitored by NH-TLC (ethyl acetate, Rf = 0.30).
-
Analytical Data
-
2-phenylimidazole
1H NMR (270 MHz, DMSO-d6); δ 12.5 (dr, 1H), 7.95-7.91 (m, 2H), 7.44 (t, 2H, J = 7.3 Hz), 7.33 (t, 1H, J = 7.3 Hz), 7.24 (s, 1H), 7.02 (s, 1H)
-
Lead Reference
-
- Expanded applicability of iridium(I) NHC/phosphine catalysts in hydrogen isotope exchange processes with pharmaceutically-relevant heterocycles
References
- G. Piancatelli, F. Leonelli, Org. Synth. 2006, 83, 18.
기사 / 브로셔
[Research Articles] Synthesis of 1,2-Diamine Derivatives Using a Rhodium Catalyst
SDS
요청한 SDS를 사용할 수 없습니다.
번거롭게 해드려 죄송하지만 이 양식 보다 문의 해주십시오.
규격표
시험성적서, 각종 증명서
샘플 시험성적서
본 제품의 샘플시험성적서는 현재 준비되어 있지 않습니다.
분석 차트
죄송합니다만 찾으시는 분석차트는 없습니다.