text.skipToContent text.skipToNavigation

Maximum quantity allowed is 999

Please select the quantity

CAS RN: 100-63-0 | Product Number: P0183

Phenylhydrazine


Purity: >98.0%(GC)(T)
Synonyms:
Product Documents:
25G
₩38,900
≥40  ≥100  Contact Us
100G
₩66,600
1   39   Contact Us
500G
₩164,700
1   ≥100  Contact Us
* Please contact our distributor of SEJIN CI Co., Ltd. if you would like to purchase TCI products. The above prices do not include freight cost, customs charge and other charges to the destination. SEJIN CI Co., Ltd. (Phone: 02-2655-2480 / email:  sales@sejinci.co.kr)
* The storage conditions are subject to change without notice.

Product Number P0183
Purity / Analysis Method >98.0%(GC)(T)
Molecular Formula / Molecular Weight C__6H__8N__2 = 108.14 
Physical State (20 deg.C) Liquid
Storage Temperature Refrigerated (0-10°C)
Store Under Inert Gas Store under inert gas
Condition to Avoid Light Sensitive,Air Sensitive
CAS RN 100-63-0
Reaxys Registry Number 606080
PubChem Substance ID 87574432
SDBS (AIST Spectral DB) 561
Merck Index (14) 7293
MDL Number

MFCD00007573

Specifications
Appearance White or Colorless to Orange to Green powder to lump to clear liquid
Purity(GC) min. 98.0 %
Purity( Potassium iodate Method) min. 98.0 %
Properties (reference)
Melting Point 19 °C
Flash point 88 °C
Specific Gravity (20/20) 1.10
Refractive Index 1.61
Solubility in water Soluble
Degree of solubility in water 837 g/l   24 °C
Solubility (miscible with) Chloroform, Ether, Benzene, Alcohol
GHS
Pictogram Pictogram Pictogram Pictogram
Signal Word Danger
Hazard Statements H310 : Fatal in contact with skin.
H301 + H331 : Toxic if swallowed or if inhaled.
H315 : Causes skin irritation.
H319 : Causes serious eye irritation.
H370 : Causes damage to organs.
H372 : Causes damage to organs through prolonged or repeated exposure.
H317 : May cause an allergic skin reaction.
H341 : Suspected of causing genetic defects.
H350 : May cause cancer.
H400 : Very toxic to aquatic life.
H227 : Combustible liquid.
Precautionary Statements P501 : Dispose of contents/ container to an approved waste disposal plant.
P273 : Avoid release to the environment.
P272 : Contaminated work clothing should not be allowed out of the workplace.
P260 : Do not breathe dust/ fume/ gas/ mist/ vapors/ spray.
P270 : Do not eat, drink or smoke when using this product.
P262 : Do not get in eyes, on skin, or on clothing.
P202 : Do not handle until all safety precautions have been read and understood.
P210 : Keep away from heat/sparks/open flames/hot surfaces. No smoking.
P201 : Obtain special instructions before use.
P271 : Use only outdoors or in a well-ventilated area.
P264 : Wash skin thoroughly after handling.
P280 : Wear protective gloves/ protective clothing/ eye protection/ face protection.
P370 + P378 : In case of fire: Use dry sand, dry chemical or alcohol-resistant foam to extinguish.
P391 : Collect spillage.
P337 + P313 : If eye irritation persists: Get medical advice/ attention.
P305 + P351 + P338 : IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P308 + P311 : IF exposed or concerned: Call a POISON CENTER/doctor.
P361 + P364 : Take off immediately all contaminated clothing and wash it before reuse.
P333 + P313 : If skin irritation or rash occurs: Get medical advice/ attention.
P301 + P310 + P330 : IF SWALLOWED: Immediately call a POISON CENTER/doctor. Rinse mouth.
P302 + P352 + P310 : IF ON SKIN: Wash with plenty of water. Immediately call a POISON CENTER/doctor.
P304 + P340 + P311 : IF INHALED: Remove person to fresh air and keep comfortable for breathing. Call a POISON CENTER/doctor.
P403 + P233 : Store in a well-ventilated place. Keep container tightly closed.
P403 + P235 : Store in a well-ventilated place. Keep cool.
P405 : Store locked up.
Related Laws:
RTECS# MV8925000
Transport Information:
UN Number UN2572
Class 6.1
Packing Group II
H.S.code* 2928.00-000
*This code is applied to the products when TCI exports from Japan and not for import in your country.
Application
Reagent for anemia model

References


Application
Direct Radical Arylation of Unactivated Arenes Using Phenyl Hydrazine

P0183

Typical Procedure: KOt-Bu (0.101 g, 0.9 mmol, 3.0 eq.), aryl iodide (0.3 mmol, 1.0 eq.) and benzene (2.8 mL) are added into a flame dried Schlenk tube under argon atmosphere. Then a 0.15 M solution of phenylhydrazine (0.2 mL, 0.03 mmol, 0.1 eq.) in benzene is added to this heterogeneous reaction mixture over 6 h using a syringe pump at 100 °C. After complete addition, the reaction mixture is stirred for an additional 24 h at 100 °C. After that it is cooled to room temperature, quenched with water (4 mL) and subsequently extracted with ethyl acetate (3 x 20 mL). The combined organic phase is washed with brine (5 mL), dried over anhydrous Na2SO4, filtered and concentrated under vacuum. The crude product is purified by flash column chromatography using pentane or a 95:05 mixture of pentane/ethyl acetate as an eluent.

References


PubMed Literature


Product Documents (Note: Some products will not have analytical charts available.)
Safety Data Sheet (SDS)
Please select Language.

The requested SDS is not available.

Please Contact Us for more information.

Specifications
C of A & Other Certificates
Please enter Lot Number Incorrect Lot Number. Please input only the 4-5 alphanumeric characters before the hyphen.

The product with the lot number searched for has been discontinued and no related documentation is available.

Sample C of A
This is a sample C of A and may not represent a recently manufactured lot of the product.

A sample C of A for this product is not available at this time.

Analytical Charts
Please enter Lot Number Incorrect Lot Number. Please input only the 4-5 alphanumeric characters before the hyphen.

The requested analytical chart is not available. Sorry for the inconvenience.

The product with the lot number searched for has been discontinued and no related documentation is available.

Other Documents

Session Status
Your session will timeout in 10 minutes. You will be redirected to the HOME page after session timeout. Please click the button to continue session from the same page. minute. You will be redirected to the HOME page after session timeout. Please click the button to continue session from the same page.

Your session has timed out. You will be redirected to the HOME page.