text.skipToContent text.skipToNavigation

Maximum quantity allowed is 999

Please select the quantity

CAS RN: | Product Number: I1309

Silver Stain Kit [for Electrophoresis]


Purity:
Synonyms:
Product Documents:
1KIT
€144.00
Contact Us 19  

*Stock available in Belgium will be delivered in 1 to 3 days
*Stock available in Japan will be delivered in 1 to 2 weeks (excludes regulated items and dry ice shipments).


Supplemental Product Information:

Product Information

  • Components : Solution-1 (Enhancing solution) 50 mL, Solution-2 (Staining solution) 50 mL, Solution-3 (Developer solution #1) 50 mL, Solution-4 (Developer solution #2) 50 mL
  • Size : 50 tests (90 mm x 80 mm, 1 mm gel)

Description

  • Silver staining is a highly-sensitive and rapid detection method for SDS-PAGE separated proteins or nucleic acids. It is several times more sensitive than the commonly used EtBr or CBB staining methods.

Direction for Use

[Solution Preparation]

  • Agitate each included solution well, and prepare the following 4 solutions in advance.
    The volumes of reagents given below is based on a gel size of 90 mm x 80 mm x 1 mm. For different sizes of gel, the volume of reagents should be adjusted accordingly. For methanol and acetic acid, it is recommended to use special grade or any other higher grade.
  • Fixing Solution : Deionized water : 40 mL + Methanol : 50 mL + Acetic acid : 10 mL + Solution-1 (Enhancing solution) : 1 mL
  • Staining Solution : Deionized water : 100 mL + Solution-2 (Staining solution) : 1 mL
  • Developer Solution : Deionized water : 200 mL + Solution-3 (Developer solution #1) : 1 mL + Solution-4 (Developer solution #2) : 1 mL
  • Stop Solution : Deionized water : 100 mL + Acetic acid : 1 mL

[Usage]

  1. Soak the gel in 100 mL of Fixing Solution in a clean tray and incubate it with shaking for 10 minutes.
  2. Remove the solution from step 1, and wash gel with 100 mL of deionized water with shaking for 10 minutes.
    (Repeat a total of three times)
  3. Remove the solution from step 2, and add 100 mL of Staining Solution. Allow to incubate with shaking for 5 minutes.
    *When disposing of Solution-2 (i.e. Staining Solution), add hydrochloric acid or sodium chloride to the container to precipitate out silver chloride.
  4. Remove the solution from step 3, and add 100 mL of deionized water. Incubate with shaking for 30 seconds.
  5. Remove the solution from step 4, and add 100 mL of Developer Solution. Incubate with shaking for 30 seconds.
  6. Remove the solution from step 5, and add 100 mL of Developer Solution. Allow to incubate with shaking until developed bands appear.
    *Developing time will vary by sample, temperature, and thickness of gel, so adjust accordingly.
    *A 90 mm x 80 mm x 1 mm gel will take approximately 5-10 minutes.
  7. Remove the solution from step 6, and add 100 mL of Stop Solution. Incubate with shaking for 10 minutes.
  8. Remove the solution from step 7, and wash with 100 mL of deionized water, incubating with shaking for 5 minutes between washes. (Repeat a total of three times.)

Storage

  • Store at 4 ºC. This product is photosensitive and should be protected from light. Use within 1 year.

Product Number I1309
Physical State (20 deg.C) Liquid
Storage Temperature Refrigerated (0-10°C)
Condition to Avoid Heat Sensitive
Specifications
Properties (reference)
GHS
Related Laws:
Transport Information:
UN Number UN3316
Class 9
HS Number 3822190090
Product Documents (Note: Some products will not have analytical charts available.)
Safety Data Sheet (SDS)
Please select Language.

The requested SDS is not available.

Please Contact Us for more information.

Specifications
C of A & Other Certificates
Please enter Lot Number Incorrect Lot Number. Please input only the 4-5 alphanumeric characters before the hyphen.

The product with the lot number searched for has been discontinued and no related documentation is available.

Sample C of A
This is a sample C of A and may not represent a recently manufactured lot of the product.

A sample C of A for this product is not available at this time.

Analytical Charts
Please enter Lot Number Incorrect Lot Number. Please input only the 4-5 alphanumeric characters before the hyphen.

The requested analytical chart is not available. Sorry for the inconvenience.

The product with the lot number searched for has been discontinued and no related documentation is available.

Other Documents

Session Status
Your session will timeout in 10 minutes. You will be redirected to the HOME page after session timeout. Please click the button to continue session from the same page. minute. You will be redirected to the HOME page after session timeout. Please click the button to continue session from the same page.

Your session has timed out. You will be redirected to the HOME page.