Maximum quantity allowed is 999
Please select the quantity
CAS RN: 163927-30-8 | Product Number: A5578
(S)-(+)-NBD-Py-NCS [=(S)-(+)-4-(3-Isothiocyanatopyrrolidin-1-yl)-7-nitro-2,1,3-benzoxadiazole] [HPLC Labeling Reagent for e.e. Determination]
Purity: >98.0%(HPLC)
Synonyms:
- (S)-(+)-4-(3-Isothiocyanatopyrrolidin-1-yl)-7-nitrobenzofurazan
- (S)-(+)-4-(3-Isothiocyanatopyrrolidin-1-yl)-7-nitro-2,1,3-benzoxadiazole
Product Documents:
Size | Unit Price | Same Day | 2-3 Business Days | Other Lead Time | Shipping Information |
---|---|---|---|---|---|
100MG |
$268.00
|
20 | 0 | Contact Us |
* Please contact our distributors or
TCI
to order our products. The above prices do not include freight cost, customs, and other charges to the destination.
* The storage conditions are subject to change without notice.
Product Number | A5578 |
Purity / Analysis Method | >98.0%(HPLC) |
Molecular Formula / Molecular Weight | C__1__1H__9N__5O__3S = 291.29 |
Physical State (20 deg.C) | Solid |
Storage Temperature | Refrigerated (0-10°C) |
Store Under Inert Gas | Store under inert gas |
Condition to Avoid | Air Sensitive,Heat Sensitive |
Packaging and Container | 100MG-Glass Bottle with Plastic Insert (View image) |
CAS RN | 163927-30-8 |
PubChem Substance ID | 87563195 |
MDL Number | MFCD02093435 |
Specifications
Appearance | Light yellow to Brown powder to crystal |
Purity(HPLC) | min. 98.0 area% |
Optical purity(LC) | min. 99.0 ee% |
Effect test of HPLC derivatization | Effective as labeling agent for DL-Valine, DL-Phenylalanine |
NMR | confirm to structure |
Properties (reference)
Specific Rotation | 575° (C=0.2,CH3CN) |
GHS
Pictogram | |
Signal Word | Warning |
Hazard Statements | H302 + H332 : Harmful if swallowed or if inhaled. H315 : Causes skin irritation. H319 : Causes serious eye irritation. H335 : May cause respiratory irritation. |
Precautionary Statements | P501 : Dispose of contents/ container to an approved waste disposal plant. P261 : Avoid breathing dust/ fume/ gas/ mist/ vapors/ spray. P270 : Do not eat, drink or smoke when using this product. P271 : Use only outdoors or in a well-ventilated area. P264 : Wash skin thoroughly after handling. P280 : Wear protective gloves/ eye protection/ face protection. P302 + P352 : IF ON SKIN: Wash with plenty of water. P337 + P313 : If eye irritation persists: Get medical advice/ attention. P305 + P351 + P338 : IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. P362 + P364 : Take off contaminated clothing and wash it before reuse. P332 + P313 : If skin irritation occurs: Get medical advice/ attention. P301 + P312 + P330 : IF SWALLOWED: Call a POISON CENTER/doctor if you feel unwell. Rinse mouth. P304 + P340 + P312 : IF INHALED: Remove person to fresh air and keep comfortable for breathing. Call a POISON CENTER/doctor if you feel unwell. P403 + P233 : Store in a well-ventilated place. Keep container tightly closed. P405 : Store locked up. |
Related Laws:
Transport Information:
H.S.code* | 2934.99-000 |
Application
HPLC Labeling Reagent for Chiral Amines
The compound 1 is an HPLC fluorescence labeling reagent for optical purity determination. This compound easily reacts with amino groups, which are directly linked to an asymmetric carbon atom, and produces diastereomers of thiourea. These diasteromers can be separated by reversed phase HPLC, and an excellent chromatogram can be obtained by fluorescence detection at the excitation and emission wavelengths of 488 nm and 590 nm, respectively.
Since both (R)- and (S)-isomers of the derivatization reagents are commercially available on the market, it is possible to change the elution order of the derivatized diastereomers by selecting either enantiomer of the derivatization reagent. Thus, an enantiomer of the aminocompound, whose existing quantity is very small, can be eluted out first and quantified with high precision. Moreover, there are reports for the application of these isomers to Edman Degradation.
Since both (R)- and (S)-isomers of the derivatization reagents are commercially available on the market, it is possible to change the elution order of the derivatized diastereomers by selecting either enantiomer of the derivatization reagent. Thus, an enantiomer of the aminocompound, whose existing quantity is very small, can be eluted out first and quantified with high precision. Moreover, there are reports for the application of these isomers to Edman Degradation.
Application example:
Add 10 µL of 5 mM HPLC labeling reagent 1 / acetonitrile solution in 10 µL solution of 1 mM amine / acetonitrile-H2O (1:1) solution (containing 2% triethylamine) to a vessel. Close the cap of the reaction vessel and incubate the mixture at 55 °C for 10 min. Then, add 480 µL of a mixture solution of 1 M acetic acid and acetonitrile-H2O (1:1) solution, and dilute this reactant mixture 10x by acetonitrile. Use 5 µL of this diluted solution as an HPLC sample solution.
Add 10 µL of 5 mM HPLC labeling reagent 1 / acetonitrile solution in 10 µL solution of 1 mM amine / acetonitrile-H2O (1:1) solution (containing 2% triethylamine) to a vessel. Close the cap of the reaction vessel and incubate the mixture at 55 °C for 10 min. Then, add 480 µL of a mixture solution of 1 M acetic acid and acetonitrile-H2O (1:1) solution, and dilute this reactant mixture 10x by acetonitrile. Use 5 µL of this diluted solution as an HPLC sample solution.
TCI Products Pamphlet
HPLC Labeling Reagents ( PDF 10MB )
HPLC Labeling Reagents ( PDF 10MB )
References
- 1)T. Toyo'oka, Y.-M. Liu, Analyst 1995, 120, 385.
- 2)T. Toyo'oka, Y.-M. Liu, J. Chromatogr. A 1995, 689, 23.
- 3)T. Toyo'oka, Y.-M. Liu, Chromatographia 1995, 40, 645.
- 4)Y.-M. Liu, J.-R. Miao, T. Toyo'oka, Anal. Chim. Acta 1995, 314, 169.
PubMed Literature
Articles/Brochures
TCIMAIL
Product Documents (Note: Some products will not have analytical charts available.)
Safety Data Sheet (SDS)
Please select Language.
The requested SDS is not available.
Please Contact Us for more information.
Specifications
C of A & Other Certificates
Please enter Lot Number
Incorrect Lot Number. Please input only the 4-5 alphanumeric characters before the hyphen.
Sample C of A
This is a sample C of A and may not represent a recently manufactured lot of the product.
A sample C of A for this product is not available at this time.
Analytical Charts
Please enter Lot Number
Incorrect Lot Number. Please input only the 4-5 alphanumeric characters before the hyphen.
The requested analytical chart is not available. Sorry for the inconvenience.