text.skipToContent text.skipToNavigation

Maximum quantity allowed is 999

Please select the quantity

CAS RN: 5341-61-7 | Product Number: H0170

Hydrazine Dihydrochloride


Purity: >98.0%(T)
Synonyms:
  • Hydrazinium Dichloride
Product Documents:
25G
¥140.00
9   1   5  
100G
¥250.00
3   Contact Us Contact Us
500G
¥360.00
Contact Us 1   ≥100 

* For order or inquiry, please contact Our Authorized Distributors.
*TCI frequently reviews storage conditions to optimize them. Please note that the latest information on the storage temperature for the products is described on our website.
* To send your quote request for bulk quantities, please click on the "Request Bulk Quote" button. Please note that we cannot offer bulk quantities for some products.


Product Number H0170
Purity / Analysis Method >98.0%(T)
Molecular Formula / Molecular Weight H__4N__2·2HCl = 104.96 
Physical State (20 deg.C) Solid
Storage Temperature Room Temperature (Recommended in a cool and dark place, <15°C)
Store Under Inert Gas Store under inert gas
Condition to Avoid Air Sensitive,Hygroscopic
CAS RN 5341-61-7
Reaxys Registry Number 13198600
PubChem Substance ID 87570604
Merck Index (14) 4770
MDL Number

MFCD00064543

Specifications
Appearance White powder to crystal
Purity( Potassium iodate Method) min. 98.0 %
Properties (reference)
Melting Point 200 °C(dec.)
Solubility in water Soluble
Solubility (slightly sol. in) Alcohol
GHS
Pictogram Pictogram Pictogram Pictogram Pictogram
Signal Word Danger
Hazard Statements H300 + H310 + H330 : Fatal if swallowed, in contact with skin or if inhaled.
H314 : Causes severe skin burns and eye damage.
H317 : May cause an allergic skin reaction.
H350 : May cause cancer.
H410 : Very toxic to aquatic life with long lasting effects.
Precautionary Statements P501 : Dispose of contents/ container to an approved waste disposal plant.
P273 : Avoid release to the environment.
P272 : Contaminated work clothing should not be allowed out of the workplace.
P260 : Do not breathe dust/ fume/ gas/ mist/ vapors/ spray.
P270 : Do not eat, drink or smoke when using this product.
P262 : Do not get in eyes, on skin, or on clothing.
P202 : Do not handle until all safety precautions have been read and understood.
P201 : Obtain special instructions before use.
P271 : Use only outdoors or in a well-ventilated area.
P264 : Wash skin thoroughly after handling.
P280 : Wear protective gloves/ protective clothing/ eye protection/ face protection.
P284 : Wear respiratory protection.
P391 : Collect spillage.
P308 + P313 : IF exposed or concerned: Get medical advice/ attention.
P361 + P364 : Take off immediately all contaminated clothing and wash it before reuse.
P303 + P361 + P353 : IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water/shower.
P333 + P313 : If skin irritation or rash occurs: Get medical advice/ attention.
P301 + P330 + P331 : IF SWALLOWED: Rinse mouth. Do NOT induce vomiting.
P301 + P310 + P330 : IF SWALLOWED: Immediately call a POISON CENTER/doctor. Rinse mouth.
P304 + P340 + P310 : IF INHALED: Remove person to fresh air and keep comfortable for breathing. Immediately call a POISON CENTER/doctor.
P305 + P351 + P338 + P310 : IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Immediately call a POISON CENTER/doctor.
P403 + P233 : Store in a well-ventilated place. Keep container tightly closed.
P405 : Store locked up.
Related Laws:
RTECS# MV2298000
Transport Information:
UN Number UN3290
Class 6.1 / 8
Packing Group II
Customs Control Conditions (Q)
PubMed Literature


Product Documents (Note: Some products will not have analytical charts available.)
Safety Data Sheet (SDS)
Please select Language.

The requested SDS is not available.

Please Contact Us for more information.

Specifications
C of A & Other Certificates
Please enter Lot Number Incorrect Lot Number. Please input only the 4-5 alphanumeric characters before the hyphen.

The product with the lot number searched for has been discontinued and no related documentation is available.

Sample C of A
This is a sample C of A and may not represent a recently manufactured lot of the product.

A sample C of A for this product is not available at this time.

Analytical Charts
Please enter Lot Number Incorrect Lot Number. Please input only the 4-5 alphanumeric characters before the hyphen.

The requested analytical chart is not available. Sorry for the inconvenience.

The product with the lot number searched for has been discontinued and no related documentation is available.

Other Documents

Session Status
Your session will timeout in 10 minutes. You will be redirected to the HOME page after session timeout. Please click the button to continue session from the same page. minute. You will be redirected to the HOME page after session timeout. Please click the button to continue session from the same page.