CAS RN: 75-05-8 | Product Number: A0293

Acetonitrile [for Spectrophotometry]


Purity: >99.5%(GC)
Synonyms:
  • Methyl Cyanide
  • ACN
Product Documents:
100ML
¥425.00
5   Contact Us 1  

* For order or inquiry, please contact Our Authorized Distributors.
*TCI frequently reviews storage conditions to optimize them. Please note that the latest information on the storage temperature for the products is described on our website.
* To send your quote request for bulk quantities, please click on the "Request Bulk Quote" button. Please note that we cannot offer bulk quantities for some products.


Product Number A0293
Purity / Analysis Method >99.5%(GC)
Molecular Formula / Molecular Weight C__2H__3N = 41.05 
Physical State (20 deg.C) Liquid
Storage Temperature Room Temperature (Recommended in a cool and dark place, <15°C)
Store Under Inert Gas Store under inert gas
Condition to Avoid Hygroscopic
CAS RN 75-05-8
Reaxys Registry Number 741857
PubChem Substance ID 87561946
SDBS (AIST Spectral DB) 1218
Merck Index (14) 70
MDL Number

MFCD00001878

Specifications
Appearance Colorless clear liquid
Purity(GC) min. 99.5 %
Absorbance(210nm) max. 0.100
Absorbance(220nm) max. 0.020
Absorbance(230nm) max. 0.010
Absorbance(400nm) max. 0.010
NMR confirm to structure
Properties (reference)
Melting Point -46 °C
Boiling Point 82 °C
Flash point 10 °C
Specific Gravity (20/20) 0.78
Refractive Index 1.34
Solubility in water Completely miscible
Solubility (miscible with) Ether, Alcohol
GHS
Pictogram Pictogram Pictogram Pictogram
Signal Word Danger
Hazard Statements H311 : Toxic in contact with skin.
H332 : Harmful if inhaled.
H303 : May be harmful if swallowed.
H319 : Causes serious eye irritation.
H370 : Causes damage to organs.
H373 : May cause damage to organs through prolonged or repeated exposure.
H225 : Highly flammable liquid and vapor.
Precautionary Statements P501 : Dispose of contents/ container to an approved waste disposal plant.
P260 : Do not breathe dust/ fume/ gas/ mist/ vapors/ spray.
P270 : Do not eat, drink or smoke when using this product.
P240 : Ground/bond container and receiving equipment.
P210 : Keep away from heat/sparks/open flames/hot surfaces. No smoking.
P233 : Keep container tightly closed.
P243 : Take precautionary measures against static discharge.
P241 : Use explosion-proof electrical/ ventilating/ lighting/ equipment.
P242 : Use only non-sparking tools.
P271 : Use only outdoors or in a well-ventilated area.
P264 : Wash skin thoroughly after handling.
P280 : Wear protective gloves/ eye protection/ face protection.
P370 + P378 : In case of fire: Use dry sand, dry chemical or alcohol-resistant foam to extinguish.
P337 + P313 : If eye irritation persists: Get medical advice/ attention.
P305 + P351 + P338 : IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P308 + P311 : IF exposed or concerned: Call a POISON CENTER/doctor.
P361 + P364 : Take off immediately all contaminated clothing and wash it before reuse.
P303 + P361 + P353 : IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water/shower.
P304 + P340 + P312 : IF INHALED: Remove person to fresh air and keep comfortable for breathing. Call a POISON CENTER/doctor if you feel unwell.
P403 + P235 : Store in a well-ventilated place. Keep cool.
P405 : Store locked up.
Related Laws:
CN Number 2622
RTECS# AL7700000
Transport Information:
UN Number UN1648
Class 3
Packing Group II
Customs Control Conditions (Q)
PubMed Literature


Product Documents (Note: Some products will not have analytical charts available.)
Safety Data Sheet (SDS)
Please select Language.

The requested SDS is not available.

Please Contact Us for more information.

Specifications
C of A & Other Certificates
Please enter Lot Number Incorrect Lot Number. Please input only the 4-5 alphanumeric characters before the hyphen.

The product with the lot number searched for has been discontinued and no related documentation is available.

Sample C of A
This is a sample C of A and may not represent a recently manufactured lot of the product.

A sample C of A for this product is not available at this time.

Analytical Charts
Please enter Lot Number Incorrect Lot Number. Please input only the 4-5 alphanumeric characters before the hyphen.

The requested analytical chart is not available. Sorry for the inconvenience.

The product with the lot number searched for has been discontinued and no related documentation is available.

Other Documents

Session Status
Your session will timeout in 10 minutes. You will be redirected to the HOME page after session timeout. Please click the button to continue session from the same page. minute. You will be redirected to the HOME page after session timeout. Please click the button to continue session from the same page.

Your session has timed out. You will be redirected to the HOME page.