Fabrication and Evaluation of Organic Field-Effect Transistors (OFETs) : TIPS Pentacene

TIPS Pentacene [B5942]

6,13-Bis(triisopropylsilylethynyl)pentacene [for organic electronics]
TIPS Pentacene
CAS RN: 373596-08-8
Product Number: B5942

Performance of TIPS Pentacene [B5942]-based OFETs

Fabrication method and evaluation of vacuum-deposited TIPS Pentacene [B5942]-based OFETs


Table. OFETs Characteristics of TIPS Pentacene [B5942]-based OFETs

Entry Fabrication Method Device Configuration SAM Treatment Polarity μ (cm2 V−1 s−1) Vth (V) Ion/Ioff
Entry1 Fabrication MethodSpin-coating Device ConfigurationBCBG SAM TreatmentHMDS (SiO2)
PFBT (Au)
Polarityp μ (cm2 V−1 s−1)0.12 Vth (V)‒1.2 Ion/Ioff105

Figure. Transfer curves in the saturated region)

Figure. Transfer curves in the saturated region


Experimental details

Fabrication and evaluation of vacuum-deposited TIPS Pentacene [B5942]-based OFETs

< Substrate >
  • HMDS-treated Si/SiO2 (thickness of SiO2:200 nm) + with PFBT-treated Au electrodes (thickness of Au:40 nm)

< Vacuum Deposition >
  • Deposition rate of Au: 0.2 Å/s, (under a pressure of ∼10−4 Pa)

< Self-Assembly Monolayer (SAM) Treatment >
  • PFBT [P0861] (For Au surface treatment) + HMDS [H0089] (For Si/SiO2 surface treatment)
    1. UV/O3 treatment (20 min)
    2. Immersion in PFBT [P0861] solution (0.01 M toluene, 3 min, Air)
    3. Exposure to vapor (IPA, 1 min)
    4. Spin-coating of HMDS [H0089] (4000 RPM, 40 sec, Air)
    5. Exposure to vapor (IPA, 1 min)

< Spin-coating >
< Device configuration >
  • [n+-Si/SiO2 (200 nm) / Au (40 nm) / TIPS Pentacene [B5942] (15 nm) ]
  • Bottom-Contact Bottom-Gate Type (BCBG)
  • Channel Length: 50 μm
  • Channel width: 1.5 mm

< Evaluation condition >
  • Under N2
  • Field-effect mobilities (μ) were determined from the transfer curves in the saturation regime using the following equation:
    ID = (W/2L) μ Ci (VGVth)2
Sitzungsstatus
Ihre Sitzung wird in 10 Minuten beendet. Sie werden nach dem Ablauf der Sitzung auf die Startseite umgeleitet. Bitte klicken Sie auf die Schaltfläche, um die Sitzung auf derselben Seite fortzusetzen. Minute beendet. Sie werden nach dem Ablauf der Sitzung auf die Startseite umgeleitet. Bitte klicken Sie auf die Schaltfläche, um die Sitzung auf derselben Seite fortzusetzen.