text.skipToContent text.skipToNavigation

Maximum quantity allowed is 999

Bitte wählen Sie die Menge aus.

CAS RN: 37342-97-5 | Produkte #: Z0010

Zirconocene Chloride Hydride


Reinheit: >96.0%(T)
Synonyme
  • Bis(cyclopentadienyl)zirconium Chloride Hydride
  • Schwartz's Reagent
Produktdokumente:
1G
€26.00
2   ≥60 
5G
€83.00
13   ≥40 
25G
€385.00
3   ≥40 

*In Belgien verfügbare Lagerbestände werden in 1 bis 3 Tagen geliefert.
*In Japan verfügbare Lagerbestände werden in 1 bis 2 Wochen geliefert. (unter Ausschluss von regulierten Artikeln und Trockeneislieferungen).


Artikel # Z0010
Reinheit / Analysenmethode >96.0%(T)
Summenformel / Molekülmasse C__1__0H__1__1ClZr = 257.87 
Physikalischer Zustand (20 °C) Solid
Lagerungstemperatur Room Temperature (Recommended in a cool and dark place, <15°C)
Unter Inertgas lagern Store under inert gas
Zu vermeidende Bedingungen Light Sensitive,Air Sensitive,Moisture Sensitive
Verpackung und Behälter 1G-Glass Bottle with Plastic Insert (Bild ansehen)
CAS RN 37342-97-5
PubChem-Stoff-ID 87577928
Merck-Index (14) 8396
MDL-Nummer

MFCD02089401

Spezifikation
Appearance White to Light yellow to Light orange powder to crystal
Purity(Chelometric Titration) min. 96.0 %
Eigenschaften
GHS
Piktogramm Pictogram Pictogram Pictogram
Signalwort Gefahr
Gefahrenhinweise H302 + H312 + H332 : Gesundheitsschädlich bei Verschlucken, Hautkontakt oder Einatmen.
H314 : Verursacht schwere Verätzungen der Haut und schwere Augenschäden.
H261 : In Berührung mit Wasser entstehen entzündbare Gase.
Sicherheitshinweise P260 : Staub nicht einatmen.
P231 + P232 : Inhalt unter inertem Gas handhaben und aufbewahren. Vor Feuchtigkeit schützen.
P280 : Schutzhandschuhe/ Schutzkleidung/ Augenschutz/ Gesichtsschutz/ Gehörschutz Tragen.
P370 + P378 : Bei Brand: Trockensand, Löschpulver oder alkoholbeständigen Schaum zum Löschen verwenden.
P303 + P361 + P353 : BEI BERÜHRUNG MIT DER HAUT (oder dem Haar): Alle kontaminierten Kleidungsstücke sofort ausziehen. Haut mit Wasser abwaschen.
P304 + P340 + P310 : BEI EINATMEN: Die Person an die frische Luft bringen und für ungehinderte Atmung sorgen. Sofort GIFTINFORMATIONSZENTRUM/Arzt anrufen.
P305 + P351 + P338 + P310 : BEI KONTAKT MIT DEN AUGEN: Einige Minuten lang behutsam mit Wasser spülen. Eventuell vorhandene Kontaktlinsen nach Möglichkeit entfernen. Weiter spülen. Sofort GIFTINFORMATIONSZENTRUM/Arzt anrufen.
Verwandte Gesetze:
EC-Nummern 253-479-5
Transportinformationen:
UN-Nummer UN3131
Klasse 4.3 / 8
Verpackungsgruppe (DOT-AIR) II
HS-Nr. (Import / Export) (TCI-E) 2931900090
Anwendung
TCI Practical Example: Reduction of Amide Group Using Zirconocene Chloride Hydride

TCI Practical Example: Reduction of Amide Group Using Zirconocene Chloride Hydride

Used Chemicals

Procedure

Zirconocene chloride hydride (0.43 g, 1.68 mmol) was added to a reaction vessel and dried in vacuo for 3 hours. Then, a THF solution (4.1 mL) of N,N-diethylnicotinamide (200 mg, 1.12 mmol) was added under argon atmosphere and the reaction mixture was stirred at room temperature for 30 minutes. The mixture was purified by chromatography on silica gel (hexane:ethyl acetate = 2:1) to give nicotinaldehyde as a brown oil (80.0 mg, 0.07 mmol, 60% yield).

Experimenter’s Comments

The reaction solution was monitored by TLC (hexane:ethyl acetate = 1:1) and UPLC.
The reaction vessel was dried up before use.

Analytical Data

Nicotinaldehyde

1H NMR (400 MHz, DNSO-d6); δ 10.09 (s, 1H), 9.07 (d, J = 1.4 Hz, 1H), 8.84 (dd, J = 5.0 Hz, 1.8 Hz, 1H), 8.23 (dt, J = 7.8 Hz, 2.1 Hz, 1H), 7.62 (dd, J = 8.5 Hz, 2.1 Hz, 1H).

Lead Reference


PubMed Literatur


Artikel / Broschüren

Produktdokumente (Hinweis: Für einige Produkte sind keine Analysediagramme verfügbar.)
Sicherheitsdatenblatt (SDB)
Bitte wählen Sie Sprache.

Das angeforderte SDB ist nicht verfügbar.

Bitte Kontaktieren Sie uns für mehr Informationen.

Spezifikationsdokumenten
AZ & andere Zertifikate
Bitte geben Sie die Lotnummer ein Falsche Chargennummer wurde eingegeben. Bitte geben Sie nur 4-5 alphanumerische Zeichen vor dem Bindestrich ein.

Das Produkt mit der gesuchten Chargennummer wurde abgekündigt und es ist keine entsprechende Dokumentation verfügbar.

Muster-AZ
Dies ist ein Muster-AZ und repräsentiert möglicherweise nicht eine kürzlich hergestellte Charge des Produkts.

Ein Muster-AZ für dieses Produkt ist zur Zeit nicht verfügbar.

Analytische Diagramme
Bitte geben Sie die Lotnummer ein Falsche Chargennummer wurde eingegeben. Bitte geben Sie nur 4-5 alphanumerische Zeichen vor dem Bindestrich ein.

Das angeforderte Analysediagramm ist nicht verfügbar. Wir entschuldigen uns für die Unannehmlichkeiten.

Das Produkt mit der gesuchten Chargennummer wurde abgekündigt und es ist keine entsprechende Dokumentation verfügbar.

Andere Dokumente

Sitzungsstatus
Ihre Sitzung wird in 10 Minuten beendet. Sie werden nach dem Ablauf der Sitzung auf die Startseite umgeleitet. Bitte klicken Sie auf die Schaltfläche, um die Sitzung auf derselben Seite fortzusetzen. Minute beendet. Sie werden nach dem Ablauf der Sitzung auf die Startseite umgeleitet. Bitte klicken Sie auf die Schaltfläche, um die Sitzung auf derselben Seite fortzusetzen.

Deine Sitzung ist abgelaufen. Sie werden auf die Startseite weitergeleitet.