text.skipToContent text.skipToNavigation

Maximum quantity allowed is 999

Bitte wählen Sie die Menge aus.

CAS RN: 143112-49-6 | Produkte #: A5561

(R)-(-)-DBD-APy [=(R)-(-)-4-(N,N-Dimethylaminosulfonyl)-7-(3-aminopyrrolidin-1-yl)-2,1,3-benzoxadiazole] [HPLC Labeling Reagent for e.e. Determination]


Reinheit: >98.0%(HPLC)
Synonyme
  • (R)-(-)-4-(N,N-Dimethylaminosulfonyl)-7-(3-aminopyrrolidin-1-yl)benzofurazan
  • (R)-(-)-4-(N,N-Dimethylaminosulfonyl)-7-(3-aminopyrrolidin-1-yl)-2,1,3-benzoxadiazole
Produktdokumente:
100MG
178,00 €
1   21  

*In Belgien verfügbare Lagerbestände werden in 1 bis 3 Tagen geliefert.
*In Japan verfügbare Lagerbestände werden in 1 bis 2 Wochen geliefert. (unter Ausschluss von regulierten Artikeln und Trockeneislieferungen).


Artikel # A5561
Reinheit / Analysenmethode >98.0%(HPLC)
Summenformel / Molekülmasse C__1__2H__1__7N__5O__3S = 311.36 
Physikalischer Zustand (20 °C) Solid
Lagerungstemperatur Room Temperature (Recommended in a cool and dark place, <15°C)
Unter Inertgas lagern Store under inert gas
Zu vermeidende Bedingungen Air Sensitive
Verpackung und Behälter 100MG-Glass Bottle with Plastic Insert (Bild ansehen)
CAS RN 143112-49-6
Reaxys Registrierungsnummer 14555181
PubChem-Stoff-ID 87563178
MDL-Nummer

MFCD00191379

Spezifikation
Appearance Light yellow to Brown powder to crystal
Purity(HPLC) min. 98.0 area%
Optical purity(LC) min. 99.0 ee%
Melting point 128.0 to 132.0 °C
Specific rotation [a]20/D -3.0 to -7.0 deg(C=1, CH3CN)
Effect test of HPLC derivatization Effective as labeling agent fo Ibuprofen
NMR confirm to structure
Eigenschaften
Schmelzpunkt 130 °C
Optische Aktivität -5° (C=1,CH3CN)
GHS
Piktogramm Pictogram
Signalwort Achtung
Gefahrenhinweise H315 : Verursacht Hautreizungen.
H319 : Verursacht schwere Augenreizung.
Sicherheitshinweise P264 : Nach Gebrauch Haut gründlich waschen.
P280 : Schutzhandschuhe/ Augenschutz/ Gesichtsschutz tragen.
P302 + P352 : BEI BERÜHRUNG MIT DER HAUT: Mit viel Wasser waschen.
P337 + P313 : Bei anhaltender Augenreizung: Ärztlichen Rat einholen/ ärztliche Hilfe hinzuziehen.
P362 + P364 : Kontaminierte Kleidung ausziehen und vor erneutem Tragen waschen.
P332 + P313 : Bei Hautreizung: Ärztlichen Rat einholen/ ärztliche Hilfe hinzuziehen.
Verwandte Gesetze:
Transportinformationen:
HS-Nr. (Import / Export) (TCI-E) 2935909099
Anwendung
HPLC Labeling Reagent for Chiral Carboxylic Acids

The compound 1 is an optically active HPLC fluorescence labeling reagent, which has a 2,1,3-benzoxadiazole skeleton and an amino group, and is used for optical purity determination of carboxylic acids. Labeling of racemic carboxylic acids can be done by using a mild condition such as the Mukaiyama-Corey method, and produces diastereomers without inducing racemization. These diastereomers can be separated by reversed phase HPLC, and an excellent chromatogram can be obtained by fluorescence detection at the excitation and emission wavelengths of 470 nm and 580 nm, respectively. Since their excitation and fluorescence wavelengths are at longer wavelengths, detection has less interference by contaminants. A highly sensitive analysis can be done by eroxyoxalate chemiluminescence detection.

Application example:1)
Add 0.1 mL of 10 mM labeling reagent 1 / acetonitrile solution, 0.25 mL of 2 µM carboxylic acid / acetonitrile solution, and 0.15 mL of 10 mM 2,2’-dipyridyl disulfide-triphenylphosphine / acetonitrile solution to a vessel, and react the mixture at room temperature for 4 h. Use the resultant as an HPLC sample solution.
For example, the detection limit (S/N=2) for naproxen is 10 fmol.

References


PubMed Literatur


Artikel / Broschüren

TCIMail
Produktdokumente (Hinweis: Für einige Produkte sind keine Analysediagramme verfügbar.)
Sicherheitsdatenblatt (SDB)
Bitte wählen Sie Sprache.

Das angeforderte SDB ist nicht verfügbar.

Bitte Kontaktieren Sie uns für mehr Informationen.

Spezifikationsdokumenten
AZ & andere Zertifikate
Bitte geben Sie die Lotnummer ein Falsche Chargennummer wurde eingegeben. Bitte geben Sie nur 4-5 alphanumerische Zeichen vor dem Bindestrich ein.

Das Produkt mit der gesuchten Chargennummer wurde abgekündigt und es ist keine entsprechende Dokumentation verfügbar.

Muster-AZ
Dies ist ein Muster-AZ und repräsentiert möglicherweise nicht eine kürzlich hergestellte Charge des Produkts.

Ein Muster-AZ für dieses Produkt ist zur Zeit nicht verfügbar.

Analytische Diagramme
Bitte geben Sie die Lotnummer ein Falsche Chargennummer wurde eingegeben. Bitte geben Sie nur 4-5 alphanumerische Zeichen vor dem Bindestrich ein.

Das angeforderte Analysediagramm ist nicht verfügbar. Wir entschuldigen uns für die Unannehmlichkeiten.

Das Produkt mit der gesuchten Chargennummer wurde abgekündigt und es ist keine entsprechende Dokumentation verfügbar.

Andere Dokumente

Sitzungsstatus
Ihre Sitzung wird in 10 Minuten beendet. Sie werden nach dem Ablauf der Sitzung auf die Startseite umgeleitet. Bitte klicken Sie auf die Schaltfläche, um die Sitzung auf derselben Seite fortzusetzen. Minute beendet. Sie werden nach dem Ablauf der Sitzung auf die Startseite umgeleitet. Bitte klicken Sie auf die Schaltfläche, um die Sitzung auf derselben Seite fortzusetzen.

Deine Sitzung ist abgelaufen. Sie werden auf die Startseite weitergeleitet.