text.skipToContent text.skipToNavigation

Maximum quantity allowed is 999

Please select the quantity

CAS RN: 1068-55-9 | Product Number: I0543

Isopropylmagnesium Chloride (ca. 11% in Tetrahydrofuran, ca. 1mol/L)


Purity:
Synonyms:
Product Documents:
250G
$196.00
1   ≥80 

* Please contact our distributors or TCI to order our products. The above prices do not include freight cost, customs, and other charges to the destination.
* The storage conditions are subject to change without notice.


Supplemental Product Information:

Grignard reagents are organometallic compounds discovered by a French chemist, Victor Grignard in 1900. These compounds can be obtained as a formula “RMgX” by the reaction of halogenated hydrocarbons with magnesium metal in anhydrous solvents such as diethyl ether,1) and have been widely used in organic synthesis.

Grignard reagents are usually used as solutions, and they are typically grayish white ~ light brown clear solutions. They generally exist in an equilibrium between alkyl magnesium halides (RMgX) and dialkyl magnesium (R2Mg), which form equilibrium mixtures with complicated compositions (called “Schlenk equilibrium”).2) Furthermore, some of these species may cause precipitation due to their lower solubility. However, there is no problem in actual use.

In the case of precipitation being formed:
Please use it after gently shaking the bottle to fully disperse the suspension (If the amount of precipitation is very small, you can use the top clear layer of the suspension). Especially in cold conditions such as in winter, a large amount of precipitate may frequently form. In this case, please use it after crushing the solid with a dried glass stick. Alternatively, you can also use it the following. The bottle is put into a plastic bag and soaking in a water bath with warming at 40 degree C to dissolve the solid. Please be careful of volatilization of the organic solvent when the bottle is unsealing.

References
1) Kagaku Daijiten (Encyclopaedia Chimica), Kyoritsu Shuppan, Tokyo, 1963, Vol. 3, p. 123.
2) Yuki Kinzoku no Kagaku to Oyo, ed. by Kinki Kagaku Kogyokai Yuki Kinzoku Bukai, Asakura Publishing, Tokyo, 1962, p. 160.

Product Number I0543
Molecular Formula / Molecular Weight C__3H__7ClMg = 102.84 
Physical State (20 deg.C) Liquid
Storage Temperature Room Temperature (Recommended in a cool and dark place, <15°C)
Store Under Inert Gas Store under inert gas
Condition to Avoid Moisture Sensitive
CAS RN 1068-55-9
Reaxys Registry Number 5073186
PubChem Substance ID 87571890
MDL Number

MFCD00000466

Specifications
Concentration(sec Butanol method) 10.5 to 12.0 w/w%
Properties (reference)
GHS
Pictogram Pictogram Pictogram Pictogram Pictogram
Signal Word Danger
Hazard Statements H302 : Harmful if swallowed.
H314 : Causes severe skin burns and eye damage.
H371 : May cause damage to organs.
H372 : Causes damage to organs through prolonged or repeated exposure.
H351 : Suspected of causing cancer.
H335 : May cause respiratory irritation.
H225 : Highly flammable liquid and vapor.
H260 : In contact with water releases flammable gases which may ignite spontaneously.
Precautionary Statements P501 : Dispose of contents/ container to an approved waste disposal plant.
P223 : Do not allow contact with water.
P260 : Do not breathe dust/ fume/ gas/ mist/ vapors/ spray.
P270 : Do not eat, drink or smoke when using this product.
P202 : Do not handle until all safety precautions have been read and understood.
P240 : Ground/bond container and receiving equipment.
P231 + P232 : Handle under inert gas. Protect from moisture.
P210 : Keep away from heat/sparks/open flames/hot surfaces. No smoking.
P233 : Keep container tightly closed.
P201 : Obtain special instructions before use.
P243 : Take precautionary measures against static discharge.
P241 : Use explosion-proof electrical/ ventilating/ lighting/ equipment.
P242 : Use only non-sparking tools.
P271 : Use only outdoors or in a well-ventilated area.
P264 : Wash skin thoroughly after handling.
P280 : Wear protective gloves/ protective clothing/ eye protection/ face protection.
P370 + P378 : In case of fire: Use dry sand, dry chemical or alcohol-resistant foam to extinguish.
P335 + P334 : Brush off loose particles from skin. Immerse in cool water/ wrap in wet bandages.
P308 + P311 : IF exposed or concerned: Call a POISON CENTER/doctor.
P303 + P361 + P353 : IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water/shower.
P301 + P330 + P331 : IF SWALLOWED: Rinse mouth. Do NOT induce vomiting.
P363 : Wash contaminated clothing before reuse.
P301 + P312 + P330 : IF SWALLOWED: Call a POISON CENTER/doctor if you feel unwell. Rinse mouth.
P304 + P340 + P310 : IF INHALED: Remove person to fresh air and keep comfortable for breathing. Immediately call a POISON CENTER/doctor.
P305 + P351 + P338 + P310 : IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Immediately call a POISON CENTER/doctor.
P403 + P233 : Store in a well-ventilated place. Keep container tightly closed.
P402 + P404 : Store in a dry place. Store in a closed container.
P403 + P235 : Store in a well-ventilated place. Keep cool.
P405 : Store locked up.
Related Laws:
Transport Information:
UN Number UN3399
Class 4.3 / 3
Packing Group I
H.S.code* 2931.90-000
*This code is applied to the products when TCI exports from Japan and not for import in your country.

Articles/Brochures

TCIMAIL
Product Documents (Note: Some products will not have analytical charts available.)
Safety Data Sheet (SDS)
Please select Language.

The requested SDS is not available.

Please Contact Us for more information.

Specifications
C of A & Other Certificates
Please enter Lot Number Incorrect Lot Number. Please input only the 4-5 alphanumeric characters before the hyphen.

The product with the lot number searched for has been discontinued and no related documentation is available.

Sample C of A
This is a sample C of A and may not represent a recently manufactured lot of the product.

A sample C of A for this product is not available at this time.

Analytical Charts
Please enter Lot Number Incorrect Lot Number. Please input only the 4-5 alphanumeric characters before the hyphen.

The requested analytical chart is not available. Sorry for the inconvenience.

The product with the lot number searched for has been discontinued and no related documentation is available.

Other Documents

Session Status
Your session will timeout in 10 minutes. You will be redirected to the HOME page after session timeout. Please click the button to continue session from the same page. minute. You will be redirected to the HOME page after session timeout. Please click the button to continue session from the same page.

Your session has timed out. You will be redirected to the HOME page.