CAS RN: 143112-51-0 | 產品號碼: A5563
(R)-(-)-NBD-APy [=(R)-(-)-4-Nitro-7-(3-aminopyrrolidin-1-yl)-2,1,3-benzoxadiazole] [HPLC Labeling Reagent for e.e. Determination]
* 以上價格已含運費關稅等但一些需要海運以及乾冰運輸的產品除外,詳情請與
當地經銷商
洽詢。
* TCI會時常優化儲存條件,儲存溫度請以在線目錄為準,敬請留意。
產品號碼 | A5563 |
純度/分析方法 | >98.0%(HPLC) |
分子式 / 分子量 | C__1__0H__1__1N__5O__3 = 249.23 |
外觀與形狀(20°C) | Solid |
儲存條件 | Room Temperature (Recommended in a cool and dark place, <15°C) |
包裝和容器 | 100MG-Glass Bottle with Plastic Insert (閲覽圖片) |
CAS RN | 143112-51-0 |
PubChem Substance ID | 87563180 |
MDL編號 | MFCD00191510 |
產品規格
Appearance | Orange to Brown to Dark red powder to crystal |
Purity(HPLC) | min. 98.0 area% |
Optical purity(LC) | min. 99.0 ee% |
Effect test of HPLC derivatization | Effective as labeling agent fo Ibuprofen |
NMR | confirm to structure |
性質
比旋光 [α]D | -13° (C=0.2,CH3CN) |
GHS
圖形表示 | |
信號詞 | Warning |
危險性說明 | H315 : Causes skin irritation. H319 : Causes serious eye irritation. |
防範說明 | P264 : Wash skin thoroughly after handling. P280 : Wear protective gloves/ eye protection/ face protection. P302 + P352 : IF ON SKIN: Wash with plenty of water. P337 + P313 : If eye irritation persists: Get medical advice/ attention. P305 + P351 + P338 : IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. P362 + P364 : Take off contaminated clothing and wash it before reuse. P332 + P313 : If skin irritation occurs: Get medical advice/ attention. |
相關法規
運輸資料
HS編碼* | 2934.99-000 |
Application
HPLC Labeling Reagent for Chiral Carboxylic Acids
The compound 1 is an optically active HPLC fluorescence labeling reagent, which has a 2,1,3-benzoxadiazole skeleton and an amino group, and is used for optical purity determination of carboxylic acids. Labeling of racemic carboxylic acids can be done by using a mild condition such as the Mukaiyama-Corey method, and produces diastereomers without inducing racemization. These diastereomers can be separated by reversed phase HPLC, and an excellent chromatogram can be obtained by fluorescence detection at the excitation and emission wavelengths of 470 nm and 540 nm, respectively. Since their excitation and fluorescence wavelengths are at longer wavelengths, detection has less interference by contaminants. A highly sensitive detection can be done by using laser induced fluorescence detector.
Application example:2)
Add 0.1 mL of 10 mM labeling reagent 1 / acetonitrile solution, 0.25 mL of 2 µM carboxylic acid / acetonitrile solution, and 0.15 mL of 10 mM 2,2’-dipyridyl disulfide-triphenylphosphine / acetonitrile solution to a vessel, and react the mixture at room temperature for 4 h. Use the resultant as an HPLC sample solution.
For example, the detection limit (S/N=2) for naproxen is 15 fmol.
Add 0.1 mL of 10 mM labeling reagent 1 / acetonitrile solution, 0.25 mL of 2 µM carboxylic acid / acetonitrile solution, and 0.15 mL of 10 mM 2,2’-dipyridyl disulfide-triphenylphosphine / acetonitrile solution to a vessel, and react the mixture at room temperature for 4 h. Use the resultant as an HPLC sample solution.
For example, the detection limit (S/N=2) for naproxen is 15 fmol.
TCI Products Pamphlet
HPLC Labeling Reagents ( PDF 10MB )
HPLC Labeling Reagents ( PDF 10MB )
References
- 1)T. Toyo'oka, M. Ishibashi, T. Terao, Analyst 1992, 117, 727.
- 2)T. Toyo'oka, M. Ishibashi, T. Terao, J. Chromatogr. 1992, 625, 357.