Maximum quantity allowed is 999
请选择数量
CAS RN: 480-66-0 | 产品编码: T1888
2',4',6'-Trihydroxyacetophenone Monohydrate
![2',4',6'-Trihydroxyacetophenone Monohydrate No-Image](/medias/T1888.jpg?context=bWFzdGVyfHJvb3R8ODQyMzl8aW1hZ2UvanBlZ3xhREJtTDJnM01DODRPVEl6TkRZNU1UZzFNRFUwTDFReE9EZzRMbXB3Wnd8MTk0ZDA5NTU3NmMyZDA3NDJkM2EyNjdjMzNiZmQ0ZjU1YWYyODQxNThlYWJhN2UzZTdlZDdjNGM4YTFkZGYxMw)
技术规格
Appearance | Light orange to Yellow to Green powder to crystal |
Purity(GC) | min. 98.0 % |
Melting point | 213.0 to 223.0 °C |
Water | 8.5 to 11.0 % |
物性(参考值)
熔点 | 215 °C |
GHS
象形图 |
![]() |
信号词 | Warning |
危险性说明 | H315 : Causes skin irritation. H319 : Causes serious eye irritation. |
防范说明 | P264 : Wash skin thoroughly after handling. P280 : Wear protective gloves/ eye protection/ face protection. P302 + P352 : IF ON SKIN: Wash with plenty of water. P337 + P313 : If eye irritation persists: Get medical advice/ attention. P305 + P351 + P338 : IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. P362 + P364 : Take off contaminated clothing and wash it before reuse. P332 + P313 : If skin irritation occurs: Get medical advice/ attention. |
相关法规
RTECS# | AN0528000 |
运输信息
HS编码* | 2914.50-000 |
应用
A Matrix for MALDI TOF Mass Spectrometry
Matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry is a standard soft ionization technique in mass spectrometry. 2',4',6'-Trihydroxyacetophenone (THAP) is often used as a matrix for MALDI-TOF mass spectrometry, for nucleotide, anthocyanin and phosphorylated peptide analysis in particular. Incidentally, IUPAC defined standard terms relating to mass spectrometry in 2013 (free access).
References
- Matrix-assisted laser desorption ionization time-of-flight mass spectrometry: A powerful tool for the mass and sequence analysis of natural and modified oligonucleotides
- The study of 2,3,4-trihydroxyacetophenone and 2,4,6-trihydroxyacetophenone as matrixes for DNA detection in matrix-assisted laser desorption/ionization time-of-flight mass spectrometry
- Analysis of anthocyanins in red wine and fruit juice using MALDI-MS
- Enhanced ionization of phosphorylated peptides during MALDI TOF mass spectrometry
- Definitions of terms relating to mass spectrometry (IUPAC Recommendations 2013)
参考文献
文章/手册
TCIMail
产品文档 (部分产品的分析图谱无法提供,敬请谅解。)
化学品安全说明书(SDS)
请选择语言。
如需更多帮助,请联系我 们。
技术规格
CoA及其他文档
请输入批号
批号输入有误。请输入中横线前的4-5个字母数字字符。
示例 CoA
可下载CoA示例。注:该示例不一定是最新批次的CoA。
目前没有该产品的 CoA 示例。
分析图谱
请输入批号
批号输入有误。请输入中横线前的4-5个字母数字字符。
很抱歉,您搜索的分析图谱无法提供。