text.skipToContent text.skipToNavigation

Maximum quantity allowed is 999

Please select the quantity

CAS RN: 51429-74-4 | Product Number: P1484

Phosphomolybdic Acid Ethanol Solution [for TLC Stain]


Purity:
Synonyms:
  • PMA Ethanol Solution
Product Documents:
500ML
$138.00
39   ≥100 

* Please contact our distributors or TCI to order our products. The above prices do not include freight cost, customs, and other charges to the destination.
* The storage conditions are subject to change without notice.


Supplemental Product Information:

[Concentration]
ca. 10% Phosphomolybdic Acid

[Solvent]
Ethanol

For TLC staining, this product is a pre-mixed solution and can be used as it is.

Product Number P1484
Molecular Formula / Molecular Weight 12MoO__3·H__3PO__4 = 1,825.48 
Physical State (20 deg.C) Liquid
Storage Temperature Room Temperature (Recommended in a cool and dark place, <15°C)
Condition to Avoid Light Sensitive
CAS RN 51429-74-4
Related CAS RN 12026-57-2
PubChem Substance ID 87575533
MDL Number

MFCD00011341

Specifications
Appearance Light yellow to Yellow clear liquid
Color test to pass test
Properties (reference)
GHS
Pictogram Pictogram Pictogram Pictogram Pictogram
Signal Word Danger
Hazard Statements H314 : Causes severe skin burns and eye damage.
H360 : May damage fertility or the unborn child.
H372 : Causes damage to organs through prolonged or repeated exposure.
H373 : May cause damage to organs through prolonged or repeated exposure.
H340 : May cause genetic defects.
H335 : May cause respiratory irritation.
H336 : May cause drowsiness or dizziness.
H401 : Toxic to aquatic life.
H225 : Highly flammable liquid and vapor.
Precautionary Statements P501 : Dispose of contents/ container to an approved waste disposal plant.
P273 : Avoid release to the environment.
P270 : Do not eat, drink or smoke when using this product.
P202 : Do not handle until all safety precautions have been read and understood.
P240 : Ground and bond container and receiving equipment.
P260 : Do not breathe mist or vapours.
P210 : Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P233 : Keep container tightly closed.
P201 : Obtain special instructions before use.
P243 : Take action to prevent static discharges.
P241 : Use explosion-proof electrical/ ventilating/ lighting/ equipment.
P242 : Use non-sparking tools.
P271 : Use only outdoors or in a well-ventilated area.
P264 : Wash skin thoroughly after handling.
P280 : Wear protective gloves/ protective clothing/ eye protection/ face protection.
P370 + P378 : In case of fire: Use dry sand, dry chemical or alcohol-resistant foam to extinguish.
P308 + P313 : IF exposed or concerned: Get medical advice/ attention.
P303 + P361 + P353 : IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water.
P301 + P330 + P331 : IF SWALLOWED: Rinse mouth. Do NOT induce vomiting.
P363 : Wash contaminated clothing before reuse.
P304 + P340 + P310 : IF INHALED: Remove person to fresh air and keep comfortable for breathing. Immediately call a POISON CENTER/doctor.
P305 + P351 + P338 + P310 : IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Immediately call a POISON CENTER/doctor.
P403 + P233 : Store in a well-ventilated place. Keep container tightly closed.
P403 + P235 : Store in a well-ventilated place. Keep cool.
P405 : Store locked up.
Related Laws:
Transport Information:
UN Number UN2924
Class 3 / 8
Packing Group II
H.S.code* 3822.19-000
*This code is applied to the products when TCI exports from Japan and not for import in your country.
PubMed Literature


Articles/Brochures

Product Documents (Note: Some products will not have analytical charts available.)
Safety Data Sheet (SDS)
Please select Language.

The requested SDS is not available.

Please Contact Us for more information.

Specifications
C of A & Other Certificates
Please enter Lot Number Incorrect Lot Number. Please input only the 4-5 alphanumeric characters before the hyphen.

The product with the lot number searched for has been discontinued and no related documentation is available.

Sample C of A
This is a sample C of A and may not represent a recently manufactured lot of the product.

A sample C of A for this product is not available at this time.

Analytical Charts
Please enter Lot Number Incorrect Lot Number. Please input only the 4-5 alphanumeric characters before the hyphen.

The requested analytical chart is not available. Sorry for the inconvenience.

The product with the lot number searched for has been discontinued and no related documentation is available.

Other Documents

Session Status
Your session will timeout in 10 minutes. You will be redirected to the HOME page after session timeout. Please click the button to continue session from the same page. minute. You will be redirected to the HOME page after session timeout. Please click the button to continue session from the same page.