text.skipToContent text.skipToNavigation

Maximum quantity allowed is 999

Please select the quantity

CAS RN: 41085-99-8 | Product Number: D6202

DiI Solution [for Cell Membrane Staining]


Purity:
Synonyms:
Product Documents:
1ML
$228.00
18   1   Contact Us

* Please contact our distributors or TCI to order our products. The above prices do not include freight cost, customs, and other charges to the destination.
* The storage conditions are subject to change without notice.


Supplemental Product Information:

Product Information

  • Concentration :1 mM
  • Excitation / Emission : 553 nm / 575 nm

Description

  • DiI is a lipophilic carbocyanine dye used to label cell membranes. It emits strong fluorescence when its long hydrocarbon chains are incorporated into a lipid bilayer. This product is a ready-to-use solution of DiI which can be used as a tracer in cell fusion, cell adhesion and chemotaxis.

Storage

  • Store at room temperature (below 15 °C is recommended) and protect from light.

Directions for Use: Staining live cells

    1. Dilute DiI solution to 5 μM with culture medium.
    2. Remove medium from cells and replace with 5 μM DiI-containing medium.
    3. Incubate cells at 37 °C for 10 minutes.
    4. Remove medium and wash cells 3 times with PBS.
    5. Observe stained cell membranes via a fluorescence microscope.

Directions for Use: Staining fixed cells

    1. Remove culture medium and wash cells twice with PBS.
    2. Add 4% paraformaldehyde to cells and incubate at room temperature for 10 minutes.
    3. Dilute DiI solution to 5 μM with PBS.
    4. Remove 4% paraformaldehyde and add 5 μM DiI-containing PBS to cells.
    5. Incubate cells at 37 °C for 10 minutes.
    6. Remove medium and wash cells 3 times with PBS.
    7. Observe stained cell membranes via a fluorescence microscope.

Related Products

  • D6263 DiD Solution [for Cell Membrane Staining]

Product Number D6202
Physical State (20 deg.C) Liquid
Storage Temperature Room Temperature (Recommended in a cool and dark place, <15°C)
Condition to Avoid Light Sensitive
CAS RN 41085-99-8
Specifications
Appearance Light red to Red clear liquid
Cell staining test to pass test
Properties (reference)
Specific Gravity (20/20) 1.04
GHS
Pictogram Pictogram Pictogram Pictogram
Signal Word Danger
Hazard Statements H319 : Causes serious eye irritation.
H360 : May damage fertility or the unborn child.
H372 : Causes damage to organs through prolonged or repeated exposure.
H373 : May cause damage to organs through prolonged or repeated exposure.
H340 : May cause genetic defects.
H335 : May cause respiratory irritation.
H336 : May cause drowsiness or dizziness.
H402 : Harmful to aquatic life.
H225 : Highly flammable liquid and vapor.
Precautionary Statements P501 : Dispose of contents/ container to an approved waste disposal plant.
P273 : Avoid release to the environment.
P270 : Do not eat, drink or smoke when using this product.
P202 : Do not handle until all safety precautions have been read and understood.
P240 : Ground and bond container and receiving equipment.
P260 : Do not breathe mist or vapours.
P210 : Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P233 : Keep container tightly closed.
P201 : Obtain special instructions before use.
P243 : Take action to prevent static discharges.
P241 : Use explosion-proof electrical/ ventilating/ lighting/ equipment.
P242 : Use non-sparking tools.
P271 : Use only outdoors or in a well-ventilated area.
P264 : Wash skin thoroughly after handling.
P280 : Wear protective gloves/ protective clothing/ eye protection/ face protection.
P370 + P378 : In case of fire: Use dry sand, dry chemical or alcohol-resistant foam to extinguish.
P308 + P313 : IF exposed or concerned: Get medical advice/ attention.
P337 + P313 : If eye irritation persists: Get medical advice/ attention.
P305 + P351 + P338 : IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P303 + P361 + P353 : IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water.
P304 + P340 + P312 : IF INHALED: Remove person to fresh air and keep comfortable for breathing. Call a POISON CENTER/doctor if you feel unwell.
P403 + P233 : Store in a well-ventilated place. Keep container tightly closed.
P403 + P235 : Store in a well-ventilated place. Keep cool.
P405 : Store locked up.
Related Laws:
Transport Information:
UN Number UN1170
Class 3
Packing Group II
H.S.code* 3822.19-000
*This code is applied to the products when TCI exports from Japan and not for import in your country.

Articles/Brochures

TCIMAIL
Product Documents (Note: Some products will not have analytical charts available.)
Safety Data Sheet (SDS)
Please select Language.

The requested SDS is not available.

Please Contact Us for more information.

Specifications
C of A & Other Certificates
Please enter Lot Number Incorrect Lot Number. Please input only the 4-5 alphanumeric characters before the hyphen.

The product with the lot number searched for has been discontinued and no related documentation is available.

Sample C of A
This is a sample C of A and may not represent a recently manufactured lot of the product.

A sample C of A for this product is not available at this time.

Analytical Charts
Please enter Lot Number Incorrect Lot Number. Please input only the 4-5 alphanumeric characters before the hyphen.

The requested analytical chart is not available. Sorry for the inconvenience.

The product with the lot number searched for has been discontinued and no related documentation is available.

Other Documents

Session Status
Your session will timeout in 10 minutes. You will be redirected to the HOME page after session timeout. Please click the button to continue session from the same page. minute. You will be redirected to the HOME page after session timeout. Please click the button to continue session from the same page.

Your session has timed out. You will be redirected to the HOME page.