Maximum quantity allowed is 999
Please select the quantity
CAS RN: 99-33-2 | Product Number: A5511
3,5-Dinitrobenzoyl Chloride [for HPLC Labeling]
Purity: >99.0%(T)
Synonyms:
Product Documents:
Size | Unit Price | Same Day | 2-3 Business Days |
---|---|---|---|
5G |
$76.00
|
13 | 23 |
* Please contact our distributors or
TCI
to order our products. The above prices do not include freight cost, customs, and other charges to the destination.
* The storage conditions are subject to change without notice.
Product Number | A5511 |
Purity / Analysis Method | >99.0%(T) |
Molecular Formula / Molecular Weight | C__7H__3ClN__2O__5 = 230.56 |
Physical State (20 deg.C) | Solid |
Storage Temperature | Room Temperature (Recommended in a cool and dark place, <15°C) |
Store Under Inert Gas | Store under inert gas |
Condition to Avoid | Moisture Sensitive |
CAS RN | 99-33-2 |
Reaxys Registry Number | 990249 |
PubChem Substance ID | 87563158 |
SDBS (AIST Spectral DB) | 3430 |
Merck Index (14) | 3277 |
MDL Number | MFCD00007248 |
Specifications
Appearance | White to Orange to Green powder to crystal |
Purity(Argentometric Titration) | min. 99.0 % |
Melting point | 68.0 to 71.0 °C |
Solubility in Toluene | almost transparency |
Effect test of HPLC derivatization | Effective as labeling agent for 1-Butanol |
NMR | confirm to structure |
Properties (reference)
Melting Point | 70 °C |
Boiling Point | 201 °C/17 mmHg |
Solubility (soluble in) | Toluene, Benzene |
GHS
Pictogram | |
Signal Word | Danger |
Hazard Statements | H302 + H312 + H332 : Harmful if swallowed, in contact with skin or if inhaled. H314 : Causes severe skin burns and eye damage. H341 : Suspected of causing genetic defects. H290 : May be corrosive to metals. |
Precautionary Statements | P501 : Dispose of contents/ container to an approved waste disposal plant. P260 : Do not breathe dusts or mists. P270 : Do not eat, drink or smoke when using this product. P202 : Do not handle until all safety precautions have been read and understood. P234 : Keep only in original container. P201 : Obtain special instructions before use. P271 : Use only outdoors or in a well-ventilated area. P264 : Wash skin thoroughly after handling. P280 : Wear protective gloves/ protective clothing/ eye protection/ face protection. P390 : Absorb spillage to prevent material damage. P308 + P313 : IF exposed or concerned: Get medical advice/ attention. P362 + P364 : Take off contaminated clothing and wash it before reuse. P303 + P361 + P353 : IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water/shower. P301 + P330 + P331 : IF SWALLOWED: Rinse mouth. Do NOT induce vomiting. P301 + P312 + P330 : IF SWALLOWED: Call a POISON CENTER/doctor if you feel unwell. Rinse mouth. P304 + P340 + P310 : IF INHALED: Remove person to fresh air and keep comfortable for breathing. Immediately call a POISON CENTER/doctor. P305 + P351 + P338 + P310 : IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Immediately call a POISON CENTER/doctor. P406 : Store in corrosive resistant container with a resistant inner liner. P405 : Store locked up. |
Related Laws:
RTECS# | DM6637000 |
Transport Information:
UN Number | UN3261 |
Class | 8 |
Packing Group | III |
H.S.code* | 2916.39-000 |
Application
HPLC Labeling Reagent for Alcohols and Amines
The compound 1 is an HPLC labeling reagent, which easily reacts with a hydroxyl group or an amino group to form the corresponding ester or amide, respectively. The resultant ester or amide is stable and can reach the detector without any decomposition under reversed phase HPLC. An excellent chromatogram can be obtained by measuring at 254 nm, an absorption wavelength that is generally used for UV detection.
Application examples:
[Alcohols] 1)
Dissolve 1~5 mg of a sample in 5 mL of THF, and add 40 mg of the labeling reagent 1 and a few drops of pyridine. Close the cap of the reaction vessel and incubate the solution at 60 °C for 1 h. Cool the resultant solution to room temperature and use it as an HPLC sample.
Clean up before injection is recommended when pyridine or triethylamine is added to trap generated HCl. Generally, evaporate the solvent, extract with ether and wash the ether layer with diluted hydrochloric acid and water.
[Others]
Analysis of mono- and diethylene glycols in polyethylene glycol2), aliphatic alcohols3)
[Alcohols] 1)
Dissolve 1~5 mg of a sample in 5 mL of THF, and add 40 mg of the labeling reagent 1 and a few drops of pyridine. Close the cap of the reaction vessel and incubate the solution at 60 °C for 1 h. Cool the resultant solution to room temperature and use it as an HPLC sample.
Clean up before injection is recommended when pyridine or triethylamine is added to trap generated HCl. Generally, evaporate the solvent, extract with ether and wash the ether layer with diluted hydrochloric acid and water.
[Others]
Analysis of mono- and diethylene glycols in polyethylene glycol2), aliphatic alcohols3)
TCI Products Pamphlet
HPLC Labeling Reagents ( PDF 10MB )
HPLC Labeling Reagents ( PDF 10MB )
References
- 1)T. H. Jupille, Am. Lab. 1976, 8, 85.
- 2)M. A. Carey, H. E. Persinger, J. Chromatogr. Sci. 1972, 10, 537.
- 3)Y. Suzuki, N. Tsuchiya, Bunseki Kagaku 1981, 30, 240.
- 4)L. J. Elrod, L. B. White, S. G. Spanton, D. G. Stroz, P. J. Cugier, L. A. Luka, Anal. Chem. 1984, 56, 1786.
PubMed Literature
Articles/Brochures
TCIMAIL
Product Documents (Note: Some products will not have analytical charts available.)
Safety Data Sheet (SDS)
Please select Language.
The requested SDS is not available.
Please Contact Us for more information.
Specifications
C of A & Other Certificates
Please enter Lot Number
Incorrect Lot Number. Please input only the 4-5 alphanumeric characters before the hyphen.
Sample C of A
This is a sample C of A and may not represent a recently manufactured lot of the product.
A sample C of A for this product is not available at this time.
Analytical Charts
Please enter Lot Number
Incorrect Lot Number. Please input only the 4-5 alphanumeric characters before the hyphen.
The requested analytical chart is not available. Sorry for the inconvenience.