CAS RN: 74-88-4 | Product Number: I0060

Iodomethane (stabilized with Copper chip)


Purity: >99.5%(GC)
Synonyms:
  • Methyl Iodide (stabilized with Copper chip)
Product Documents:
10ML
$19.00
≥80  ≥100 
100ML
$58.00
38   ≥100 
300ML
$136.00
1   12  

* Please contact our distributors or TCI to order our products. The above prices do not include freight cost, customs, and other charges to the destination.
* The storage conditions are subject to change without notice.


Product Number I0060
Purity / Analysis Method >99.5%(GC)
Molecular Formula / Molecular Weight CH__3I = 141.94 
Physical State (20 deg.C) Liquid
Storage Temperature Room Temperature (Recommended in a cool and dark place, <15°C)
Store Under Inert Gas Store under inert gas
Condition to Avoid Light Sensitive,Moisture Sensitive
CAS RN 74-88-4
Reaxys Registry Number 969135
PubChem Substance ID 125309537
SDBS (AIST Spectral DB) 3048
Merck Index (14) 6087
MDL Number

MFCD00001073

Specifications
Appearance Colorless to Almost colorlessclear liquid
Purity(GC) min. 99.5 %
Properties (reference)
Boiling Point 43 °C
Specific Gravity (20/20) 2.28
Refractive Index 1.53
Solubility in water Slightly soluble
Degree of solubility in water 14 g/l   20 °C
Solubility (miscible with) Ether, Alcohol
Solubility (soluble in) Acetone
GHS
Pictogram Pictogram Pictogram Pictogram
Signal Word Danger
Hazard Statements H330 : Fatal if inhaled.
H301 : Toxic if swallowed.
H315 : Causes skin irritation.
H318 : Causes serious eye damage.
H361 : Suspected of damaging fertility or the unborn child.
H370 : Causes damage to organs.
H372 : Causes damage to organs through prolonged or repeated exposure.
H373 : May cause damage to organs through prolonged or repeated exposure.
H351 : Suspected of causing cancer.
H335 : May cause respiratory irritation.
Precautionary Statements P501 : Dispose of contents/ container to an approved waste disposal plant.
P270 : Do not eat, drink or smoke when using this product.
P202 : Do not handle until all safety precautions have been read and understood.
P260 : Do not breathe mist or vapours.
P201 : Obtain special instructions before use.
P271 : Use only outdoors or in a well-ventilated area.
P264 : Wash skin thoroughly after handling.
P280 : Wear protective gloves/ protective clothing/ eye protection/ face protection.
P284 : Wear respiratory protection.
P302 + P352 : IF ON SKIN: Wash with plenty of water.
P308 + P311 : IF exposed or concerned: Call a POISON CENTER/doctor.
P362 + P364 : Take off contaminated clothing and wash it before reuse.
P332 + P313 : If skin irritation occurs: Get medical advice/ attention.
P301 + P310 + P330 : IF SWALLOWED: Immediately call a POISON CENTER/doctor. Rinse mouth.
P304 + P340 + P310 : IF INHALED: Remove person to fresh air and keep comfortable for breathing. Immediately call a POISON CENTER/doctor.
P305 + P351 + P338 + P310 : IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Immediately call a POISON CENTER/doctor.
P403 + P233 : Store in a well-ventilated place. Keep container tightly closed.
P405 : Store locked up.
Related Laws:
RTECS# PA9450000
Transport Information:
UN Number UN2644
Class 6.1
Packing Group I
Air Transportation Forbidden for Air Transport
H.S.code* 2903.69-000
*This code is applied to the products when TCI exports from Japan and not for import in your country.
Application
Methylation of Carboxylic Acids

References


Application
Olefin Synthesis through Chugaev Elimination

Typical Procedure:
To a stirred solution of alcohol 1 (100 mg, 0.25 mmol) in THF (20 mL) is added 60% NaH (100 mg,) at 0 ℃. The reaction mixture is stirred for 2 h, followed by addition of carbon disulfie (1 mL), and the reaction mixture is stirred for an additional 1.5 h. After this period, MeI (0.5 mL) is added and the reaction mixture is allowed to come to room temperature and stirred overnight. Then ether (20 mL) is added, followed by ice-water (10 mL). The aqueous phase is extracted three times with ether. The combined organic layers are washed with brine, dried, and evaporated. The residue is purified by flash chromatography (AcOEt : Petroleum Ether = 1 : 9) to give 2 (61 mg, 0.13 mmol, Y. 51%) as a colorless oil. A solution of degassed and freshly distilled dodecane (5 mL) and 2 (61 mg, 0.13 mmol) is refluxed for 48 h at 216 ℃. Then the solvent is evaporated until 1 mL of the volume remained, followed by flash chromatography (AcOEt : Petroleum Ether = 1 : 9) to give 3 (35 mg, Y. 74%) as a colorless oil.

References


Application
Methylation of Alcohols using Methyl Iodide

Reference

  • Protection for the Hydroxyl Group, Including 1,2- and 1,3-Diols
    • P. G. M. Wuts, in Greene’s Protective Groups in Organic Synthesis, 5th ed., ed. by P. G. M. Wuts, John Wiley & Sons, Inc., Hoboken, New Jersey, 2014, Chap. 2, 17.


Application
Methylation of Alcohols using Silver(I) Oxide and Methyl Iodide

Reference

  • Protection for the Hydroxyl Group, Including 1,2- and 1,3-Diols
    • P. G. M. Wuts, in Greene’s Protective Groups in Organic Synthesis, 5th ed., ed. by P. G. M. Wuts, John Wiley & Sons, Inc., Hoboken, New Jersey, 2014, Chap. 2, 17.


Application
Methylation of Alcohols using Silver(II) Oxide and Methyl Iodide

Reference

  • Protection for the Hydroxyl Group, Including 1,2- and 1,3-Diols
    • P. G. M. Wuts, in Greene’s Protective Groups in Organic Synthesis, 5th ed., ed. by P. G. M. Wuts, John Wiley & Sons, Inc., Hoboken, New Jersey, 2014, Chap. 2, 17.


Application
Methylation of Alcohols using Silver(I) Triflate and Methyl Iodide

Reference

  • Protection for the Hydroxyl Group, Including 1,2- and 1,3-Diols
    • P. G. M. Wuts, in Greene’s Protective Groups in Organic Synthesis, 5th ed., ed. by P. G. M. Wuts, John Wiley & Sons, Inc., Hoboken, New Jersey, 2014, Chap. 2, 17.


PubMed Literature


Product Documents (Note: Some products will not have analytical charts available.)
Safety Data Sheet (SDS)
Please select Language.

The requested SDS is not available.

Please Contact Us for more information.

Specifications
C of A & Other Certificates
Please enter Lot Number Incorrect Lot Number. Please input only the 4-5 alphanumeric characters before the hyphen.

The product with the lot number searched for has been discontinued and no related documentation is available.

Sample C of A
This is a sample C of A and may not represent a recently manufactured lot of the product.

A sample C of A for this product is not available at this time.

Analytical Charts
Please enter Lot Number Incorrect Lot Number. Please input only the 4-5 alphanumeric characters before the hyphen.

The requested analytical chart is not available. Sorry for the inconvenience.

The product with the lot number searched for has been discontinued and no related documentation is available.

Other Documents

Session Status
Your session will timeout in 10 minutes. You will be redirected to the HOME page after session timeout. Please click the button to continue session from the same page. minute. You will be redirected to the HOME page after session timeout. Please click the button to continue session from the same page.

Your session has timed out. You will be redirected to the HOME page.