CAS RN: 98-95-3 | Product Number: N0758

Nitrobenzene


Purity: >99.5%(GC)
Synonyms:
Product Documents:
500G
$32.00
14   28   ≥40 

* Items in stock locally ship in 1-2 business days. Items from Japan stock are able to ship from a US warehouse within 2 weeks. Please contact TCI for lead times on items not in stock. Excludes regulated items and items that ship on ice.
* To send your quote request for bulk quantities, please click on the "Request Quote" button. Please note that we cannot offer bulk quantities for some products.
*TCI frequently reviews storage conditions to optimize them. Please note that the latest information on the storage temperature for the products is described on our website.


Product Number N0758
Purity / Analysis Method >99.5%(GC)
Molecular Formula / Molecular Weight C__6H__5NO__2 = 123.11 
Physical State (20 deg.C) Liquid
Storage Temperature Room Temperature (Recommended in a cool and dark place, <15°C)
CAS RN 98-95-3
Reaxys Registry Number 507540
PubChem Substance ID 87558281
Merck Index (14) 6588
Specifications
Appearance Light yellow to Yellow to Orange clear liquid
Purity(GC) min. 99.5 %
Properties (reference)
Melting Point 6 °C
Boiling Point 210 °C
Flash point 88 °C
Specific Gravity (20/20) 1.20
Refractive Index 1.55
Degree of solubility in water 1,797 mg/l   25 °C
Solubility (soluble in) Acetone
GHS
Pictogram Pictogram Pictogram Pictogram
Signal Word Danger
Hazard Statements H311 : Toxic in contact with skin.
H302 + H332 : Harmful if swallowed or if inhaled.
H320 : Causes eye irritation.
H361 : Suspected of damaging fertility or the unborn child.
H370 : Causes damage to organs.
H372 : Causes damage to organs through prolonged or repeated exposure.
H351 : Suspected of causing cancer.
H411 : Toxic to aquatic life with long lasting effects.
H227 : Combustible liquid.
Precautionary Statements P501 : Dispose of contents/ container to an approved waste disposal plant.
P273 : Avoid release to the environment.
P260 : Do not breathe dust/ fume/ gas/ mist/ vapors/ spray.
P270 : Do not eat, drink or smoke when using this product.
P202 : Do not handle until all safety precautions have been read and understood.
P210 : Keep away from heat/sparks/open flames/hot surfaces. No smoking.
P201 : Obtain special instructions before use.
P271 : Use only outdoors or in a well-ventilated area.
P264 : Wash skin thoroughly after handling.
P280 : Wear protective gloves/ protective clothing/ eye protection/ face protection.
P370 + P378 : In case of fire: Use dry sand, dry chemical or alcohol-resistant foam to extinguish.
P391 : Collect spillage.
P307 + P311 : IF exposed: Call a POISON CENTER or doctor/ physician.
P337 + P313 : If eye irritation persists: Get medical advice/ attention.
P305 + P351 + P338 : IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P362 : Take off contaminated clothing and wash before reuse.
P301 + P312 + P330 : IF SWALLOWED: Call a POISON CENTER/doctor if you feel unwell. Rinse mouth.
P302 + P352 + P312 : IF ON SKIN: Wash with plenty of water.Call a POISON CENTER/doctor if you feel unwell.
P304 + P340 + P312 : IF INHALED: Remove person to fresh air and keep comfortable for breathing. Call a POISON CENTER/doctor if you feel unwell.
P403 + P235 : Store in a well-ventilated place. Keep cool.
P405 : Store locked up.
Related Laws:
RTECS# DA6475000
Transport Information:
UN Number (DOT-AIR) UN1662
Class (DOT-AIR) 6.1
Packing Group (TCI-A) II
HS Number 2904.20.3500
PubMed Literature


Product Documents (Note: Some products will not have analytical charts available.)
Safety Data Sheet (SDS)
Please select Language.

The requested SDS is not available.

Please Contact Us for more information.

Specifications
C of A & Other Certificates
Please enter Lot Number Incorrect Lot Number. Please input only the 4-5 alphanumeric characters before the hyphen.

The product with the lot number searched for has been discontinued and no related documentation is available.

Sample C of A
This is a sample C of A and may not represent a recently manufactured lot of the product.

A sample C of A for this product is not available at this time.

Analytical Charts
Please enter Lot Number Incorrect Lot Number. Please input only the 4-5 alphanumeric characters before the hyphen.

The requested analytical chart is not available. Sorry for the inconvenience.

The product with the lot number searched for has been discontinued and no related documentation is available.

Other Documents

Session Status
Your session will timeout in 10 minutes. You will be redirected to the HOME page after session timeout. Please click the button to continue session from the same page. minute. You will be redirected to the HOME page after session timeout. Please click the button to continue session from the same page.

Your session has timed out. You will be redirected to the HOME page.