Maximum quantity allowed is 999
CAS RN: | 제품번호: T3741
Tissue-Clearing Reagent CUBIC-R+(M) [for Animals]
•본건의 원가격은 한국 대리점의 예상 판매가격입니다.자세한 정보가 필요하시면 연락해 주십시오.(SEJIN CI Co., Ltd. (한국총대리점) 전화 : 02-2655-2480 이메일 : sales@sejinci.co.kr)
•보관 조건은 예고없이 변경 될 수 있습니다. 제품 보관 조건의 최신 자료는 홈페이지에 기재되어 있으니 양해 부탁드립니다.
제품보충정보:
A tissue clearing method "CUBIC" has been developed by Prof. Hiroki R. Ueda and coworkers at The University of Tokyo / RIKEN. The CUBIC technique enables cyclopedic imaging at a single-cell resolution following whole-body and whole-organ clearing. CUBIC reagents which can be used in the tissue clearing method are provided by TCI.
*CUBIC reagents are commercialized under invention licenses by RIKEN, Japan.
This product name was changed from "Tissue-Clearing Reagent CUBIC-R+" to "Tissue-Clearing Reagent CUBIC-R+(M)".
Two products of CUBIC-L (Product Number: T3740), and CUBIC-R+(M) (Product Number: T3741) or CUBIC-R+(N) (Product Number: T3983) are required for tissue-clearing.
The difference between CUBIC-R+(N) (Product No. T3983) and CUBIC-R+(M) (Product No. T3741):
CUBIC-R+(N) (Product No. T3983) is inexpensive and easier to handle because it raises less precipitation. The fluorescence signal may decay, but the fluorescence signals of samples in CUBIC-R+(N) can be observed for several days after immersion.
CUBIC-R+(M) (Product No. T3741) is superior in retaining the fluorescence signal. However, at low temperatures such as in winter, it may precipitate. In that case, it can be resolved by placing the sample at 37°C for a few days.
For these reasons, it is recommended to try CUBIC-R+(N) (Product No. T3983) first and then use CUBIC-R+(M) (Product No. T3741) if fluorescence signal cannot be found.
Please see product category page or a technical guidebook (PDF) of how to use. And an insertion (PDF) is also available.
제품번호 | T3741 |
물리적 상태 (20 ℃) | Liquid |
보관 조건 | Room Temperature (Recommended in a cool and dark place, <15°C) |
Appearance | Colorless to Light orange to Yellow clear liquid |
Functionality test(fluorescence strength) | to pass test |
굴절률 | 1.52 |
픽토그램 | |
신호 워드 | Danger |
위험물 및 유해 등록 | H315 : Causes skin irritation. H319 : Causes serious eye irritation. H370 : Causes damage to organs. |
주의 사항 | P501 : Dispose of contents/ container to an approved waste disposal plant. P260 : Do not breathe dust/ fume/ gas/ mist/ vapors/ spray. P270 : Do not eat, drink or smoke when using this product. P264 : Wash skin thoroughly after handling. P280 : Wear protective gloves/ eye protection/ face protection. P302 + P352 : IF ON SKIN: Wash with plenty of water. P337 + P313 : If eye irritation persists: Get medical advice/ attention. P305 + P351 + P338 : IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. P308 + P311 : IF exposed or concerned: Call a POISON CENTER/doctor. P362 + P364 : Take off contaminated clothing and wash it before reuse. P332 + P313 : If skin irritation occurs: Get medical advice/ attention. P405 : Store locked up. |
HS 번호* | 3822.19-000 |
References
- Whole-Body Profiling of Cancer Metastasis with Single-Cell Resolution
- Chemical Landscape for Tissue Clearing based on Hydrophilic Reagents
기사 / 브로셔
SDS
요청한 SDS를 사용할 수 없습니다.
번거롭게 해드려 죄송하지만 이 양식 보다 문의 해주십시오.
규격표
시험성적서, 각종 증명서
샘플 시험성적서
본 제품의 샘플시험성적서는 현재 준비되어 있지 않습니다.
분석 차트
죄송합니다만 찾으시는 분석차트는 없습니다.