Maximum quantity allowed is 999
CAS RN: 1295-35-8 | 제품번호: B6553
Bis(1,5-cyclooctadiene)nickel(0)
•본건의 원가격은 한국 대리점의 예상 판매가격입니다.자세한 정보가 필요하시면 연락해 주십시오.( SEJIN CI Co., Ltd. (한국총대리점) 전화 : 02-2655-2480 이메일 : sales@sejinci.co.kr)
•보관 조건은 예고없이 변경 될 수 있습니다. 제품 보관 조건의 최신 자료는 홈페이지에 기재되어 있으니 양해 부탁드립니다.
제품보충정보:
[Handling Notes]
This product may be partially colored due to air-sensitivity. If the product is partially colored, we confirmed that it is not problematic for usage as a catalyst. It is recommended to use all of the product as soon as possible upon opening the ampule bottle.
제품번호 | B6553 |
Purity/Analysis Method | >95.0%(T) |
M.F. / M.W. | C__1__6H__2__4Ni = 275.06 |
물리적 상태 (20 ℃) | Solid |
보관 조건 | Frozen (-20°C) |
불활성 가스 하에서 보관 | Store under inert gas |
피해야 할 조건 | Light Sensitive,Air Sensitive,Heat Sensitive |
CAS RN | 1295-35-8 |
Reaxys-RN | 11341079 |
MDL 번호 | MFCD00058902 |
Appearance | Light yellow to Yellow Green to Brown powder to crystal |
Purity(Chelometric Titration) | min. 95.0 % |
Catalyst test | to pass test |
NMR | confirm to structure |
픽토그램 | |
신호 워드 | Danger |
위험물 및 유해 등록 | H372 : Causes damage to organs through prolonged or repeated exposure. H317 : May cause an allergic skin reaction. H334 : May cause allergy or asthma symptoms or breathing difficulties if inhaled. H350 : May cause cancer. H228 : Flammable solid. |
주의 사항 | P501 : Dispose of contents/ container to an approved waste disposal plant. P272 : Contaminated work clothing should not be allowed out of the workplace. P260 : Do not breathe dust/ fume/ gas/ mist/ vapors/ spray. P270 : Do not eat, drink or smoke when using this product. P202 : Do not handle until all safety precautions have been read and understood. P240 : Ground and bond container and receiving equipment. P210 : Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. P201 : Obtain special instructions before use. P241 : Use explosion-proof electrical/ ventilating/ lighting/ equipment. P264 : Wash skin thoroughly after handling. P280 : Wear protective gloves/ protective clothing/ eye protection/ face protection. P284 : Wear respiratory protection. P302 + P352 : IF ON SKIN: Wash with plenty of water. P370 + P378 : In case of fire: Use dry sand, dry chemical or alcohol-resistant foam to extinguish. P308 + P313 : IF exposed or concerned: Get medical advice/ attention. P362 + P364 : Take off contaminated clothing and wash it before reuse. P304 + P340 : IF INHALED: Remove person to fresh air and keep comfortable for breathing. P333 + P313 : If skin irritation or rash occurs: Get medical advice/ attention. P405 : Store locked up. |
RTECS # | QR6135000 |
UN 번호 | UN1325 |
등급 | 4.1 |
포장 그룹 | II |
HS 번호* | 2931.90-000 |
-
Used Chemicals
-
Procedure
-
Phenylboronic acid (366 mg, 3.0 mmol, 1.5 eq.), triphenylphosphine (42 mg, 0.16 mmol, 0.08 eq.), tripotassium phosphate (1.27 g, 6.0 mmol, 3.0 eq.) and Ni(cod)2 (22 mg, 0.08 mmol, 0.04 eq.) were weighed and sealed in a glove box. To this mixture, 4’-chloroacetophenone (0.26 mL, 2.0 mmol) in THF (8 mL) was added and the reaction mixture was stirred for 24 hours at r.t., and then quenched with water (15 mL). The solution was extracted with ethyl acetate (15 mL x 3) and the combined organic layer was washed with brine (15 mL), dried over sodium sulfate and filtered. The solvent was removed under reduced pressure and the residue was purified by column chromatography (on silica gel, ethyl acetate:hexane = 1:10) to give 4-acetylbiphenyl as a white solid (360 mg, 92% yield).
-
Experimenter’s Comments
-
The reaction mixture was monitored by GC.
Commercially available dry THF was used.
The functionality of the partially discolored Ni(cod)2 was verified, and it was confirmed through this experiment that the reaction proceeded without any problems.
-
Analytical Data
-
4-Acetylbiphenyl
1H NMR (400 MHz, CDCl3); δ 8.04 (d, J = 8.0 Hz, 2H), 7.69 (d, J = 8.0 Hz, 2H), 7.63 (d, J = 7.2 Hz, 2H), 7.50-7.46 (m, 2H), 7.42-7.39 (m, 1H), 2.65 (s, 3H).
-
Lead Reference
-
- Triphenylphosphine as a Ligand for Room-Temperature Ni(0)-Catalyzed Cross-Coupling Reactions of Aryl Chlorides with Arylboronic Acids
기사 / 브로셔
SDS
요청한 SDS를 사용할 수 없습니다.
번거롭게 해드려 죄송하지만 이 양식 보다 문의 해주십시오.
규격표
시험성적서, 각종 증명서
샘플 시험성적서
본 제품의 샘플시험성적서는 현재 준비되어 있지 않습니다.
분석 차트
죄송합니다만 찾으시는 분석차트는 없습니다.