text.skipToContent text.skipToNavigation

Maximum quantity allowed is 999

Please select the quantity

CAS RN: | Product Number: W0024

Western Blot Stripping Buffer [for Biochemical Research]


Purity:
Priority Assessment Chemical Substance
Synonyms:
Product Documents:
250ML
¥6,500
33   It can be shipped from Saitama warehouse on the same day* Contact Us
* Available Stock: Prompt shipment (for products) in Saitama/Hyogo warehouse. Stock In Other WH: Shipment in about 2-3 Business Days from Saitama warehouse. Please contact us if you need further information.
* The displayed price is the unit price and does not include consumption tax. The unit prices displayed are the latest and are subject to change without notice.
* To send your quote request for bulk quantities, please click on the "Request Bulk Quote" button. Please note that we cannot offer bulk quantities for some products.
*TCI frequently reviews storage conditions to optimize them. Please note that the latest information on the storage temperature for the products is described on our website.

Supplemental Product Information:

Product Information

  • Volume : 250 mL

Description

  • Western Blot Stripping Buffer is a reagent used for removing antibodies from membranes that detects chemiluminescence in Western blotting. After chemiluminescent detection, membranes treated with Stripping Buffer can be reused for antibody concentration studies or for re-detection with a different primary antibody. The Stripping Buffer is useful for saving samples and shortening the experiment time.
    Note: Dissolve the precipitation at 25-30 °C, if precipitation occurs during storage. The Stripping Buffer is acidic and corrosive. Please wear protective equipment when using it. Metal tweezers and trays should not be used with the Stripping Buffer.

Storage

  • Store at room temperature.

Direction for Use

    1. After detecting chemiluminescence, wash the membrane twice for 10 minutes with TBS-T or PBS-T buffer.
    2. Incubate the membrane with the Stripping Buffer for 30 minutes at room temperature. Use a sufficient volume of the Stripping Buffer to ensure that the membrane is completely submerged.
      Note: Depending on the affinity between the antigen and the antibody, the antibody may not be completely removed from the membrane.
    3. Wash the membrane three times for 10 minutes each with TBS-T or PBS-T buffer.
    4. Perform blocking and antigen-antibody reaction again.

Related Products

  • A3217 30% Acrylamide / Bis-acrylamide (29:1) [for Electrophoresis]
  • A3218 30% Acrylamide / Bis-acrylamide (37.5:1) [for Electrophoresis]
  • B5834 2X SDS-PAGE Sample Buffer (2-Mercaptoethanol free) [for Electrophoresis]
  • B6104 4X SDS-PAGE Sample Buffer (2-Mercaptoethanol free) [for Electrophoresis]
  • B6105 6X Sample Buffer (2-Mercaptoethanol free) [for Electrophoresis]
  • B6110 2X SDS-PAGE Sample Buffer Phenol Red (2-Mercaptoethanol free) [for Electrophoresis]
  • C3488 Coomassie Brilliant Blue G-250 (Ready-to-use solution) [for Electrophoresis]
  • G0615 Gel Negative Stain kit [for Electrophoresis]

Product Number W0024
Physical State (20 deg.C) Liquid
Storage Temperature Room Temperature (Recommended in a cool and dark place, <15°C)
Specifications
Appearance Colorless to Almost colorlessclear liquid
Functionality test to pass test
Properties (reference)
Specific Gravity (20/20) 1.00
GHS
Pictogram Pictogram
Signal Word Warning
Hazard Statements H373 : May cause damage to organs through prolonged or repeated exposure.
Precautionary Statements P501 : Dispose of contents/ container to an approved waste disposal plant.
P260 : Do not breathe dust/ fume/ gas/ mist/ vapors/ spray.
P314 : Get medical advice/ attention if you feel unwell.
Related Laws:
Chemical Substance Law (ENCS) Priority Assessment Chemical Substance
PRTR Law (New Specific Chemical) Class 1 Designated Chemical Substances
Transport Information:
Product Documents (Note: Some products will not have analytical charts available.)
Safety Data Sheet (SDS)
Please select Language.

The requested SDS is not available.

Please Contact Us for more information.

Specifications
C of A & Other Certificates
Please enter Lot Number Incorrect Lot Number. Please input only the 4-5 alphanumeric characters before the hyphen.

The product with the lot number searched for has been discontinued and no related documentation is available.

Sample C of A
This is a sample C of A and may not represent a recently manufactured lot of the product.

A sample C of A for this product is not available at this time.

Analytical Charts
Please enter Lot Number Incorrect Lot Number. Please input only the 4-5 alphanumeric characters before the hyphen.

The requested analytical chart is not available. Sorry for the inconvenience.

The product with the lot number searched for has been discontinued and no related documentation is available.

Other Documents

Session Status
Your session will timeout in 10 minutes. You will be redirected to the HOME page after session timeout. Please click the button to continue session from the same page. minute. You will be redirected to the HOME page after session timeout. Please click the button to continue session from the same page.

Your session has timed out. You will be redirected to the HOME page.