Maintenance Notice (4:30 AM - 11:00 AM December 21, 2024): This website is scheduled to be unavailable due to maintenance. We appreciate your patience and understanding.
Published TCIMAIL newest issue No.197
Maximum quantity allowed is 999
Taille | Prix unitaire | Belgique | Japon * | Quantité |
---|---|---|---|---|
25ML |
37,00 €
|
2 | 35 |
|
100ML |
94,00 €
|
2 | 9 |
|
500ML |
319,00 €
|
1 | 8 |
|
*Le délai de livraison pour des produits disponibles en stock en Belgique est 1 à 2 jours
*Le délai de livraison pour des produits disponibles en stock en Japon est 1 à 2 semaines (sauf des produits réglementés et des envois avec de la glace carbonique)
A tissue clearing method "CUBIC" has been developed by Prof. Hiroki R. Ueda and coworkers at The University of Tokyo / RIKEN. The CUBIC technique enables cyclopedic imaging at a single-cell resolution following whole-body and whole-organ clearing. CUBIC reagents which can be used in the tissue clearing method are provided by TCI.
*CUBIC reagents are commercialized under invention licenses by RIKEN, Japan.
Two products of CUBIC-L (Product Number: T3740), and CUBIC-R+(N) (Product Number: T3983) or CUBIC-R+(M) (Product Number: T3741) are required for tissue-clearing.
The difference between CUBIC-R+(N) (Product No. T3983) and CUBIC-R+(M) (Product No. T3741):
CUBIC-R+(N) (Product No. T3983) is inexpensive and easier to handle because it raises less precipitation. The fluorescence signal may decay, but the fluorescence signals of samples in CUBIC-R+(N) can be observed for several days after immersion.
CUBIC-R+(M) (Product No. T3741) is superior in retaining the fluorescence signal. However, at low temperatures such as in winter, it may precipitate. In that case, it can be resolved by placing the sample at 37°C for a few days.
For these reasons, it is recommended to try CUBIC-R+(N) (Product No. T3983) first and then use CUBIC-R+(M) (Product No. T3741) if fluorescence signal cannot be found.
Please see product category page or a technical guidebook (PDF) of how to use. And an insertion (PDF) is also available.
Numéro de produit | T3983 |
Etat physique (20 ° C) | Liquid |
Condition de stockage | Room Temperature (Recommended in a cool and dark place, <15°C) |
Appearance | Colorless to Light yellow clear liquid |
Functionality test(Tissue-Clearing) | to pass test |
Refractive index | 1.5180 to 1.5280 |
Densité (20/20) | 1.15 |
Pictogramme | |
Mot de signal | Danger |
Mentions de danger | H315 : Provoque une irritation cutanée. H319 : Provoque une sévère irritation des yeux. H370 : Risque avéré d'effets graves pour les organes. |
Conseils de prudence | P501 : Éliminer le contenu/récipient dans une installation d'élimination des déchets agréée. P260 : Ne pas respirer les brouillards ou les vapeurs. P264 : Se laver la peau soigneusement après manipulation. P280 : Porter des gants de protection/ un équipement de protection des yeux/ du visage. P337 + P313 : Si l'irritation oculaire persiste: consulter un médecin. P308 + P311 : EN CAS d’exposition prouvée ou suspectée: Appeler un CENTRE ANTIPOISON/un médecin. |
N ° SH (import / export) (TCI-E) | 3822190090 |
La FDS demandée n'est pas disponible.
Nous contacter pour plus d'informations.
Un échantillon CoA pour ce produit n'est pas disponible pour le moment.
Le tableau analytique demandé n'est pas disponible. Nous sommes désolés pour ce désagrément.