Published TCIMAIL newest issue No.197
Maximum quantity allowed is 999
Merci de sélectionner la quantité
CAS RN: 254973-02-9 | Numéro de produit: A5576
AABD-SH (=4-Acetamido-7-mercapto-2,1,3-benzoxadiazole) [for HPLC Labeling]
![AABD-SH (=4-Acetamido-7-mercapto-2,1,3-benzoxadiazole) [for HPLC Labeling] No-Image](/medias/A5576.jpg?context=bWFzdGVyfHJvb3R8NTUzOTd8aW1hZ2UvanBlZ3xhRGcxTDJnM1l5ODRPVEU1TnpReE9ESTFNRFUwTDBFMU5UYzJMbXB3Wnd8Njc4NjA0ZWRkYWNmZjQxMGNlZWQyMGI1MDQ5YTQyNGU5OTU2YTBiMDUxMGVkNWE5YWZlYTE0MGM4NDcwZjY1Mg)
Pureté: >95.0%(HPLC)
Synonymes
- 4-Acetamido-7-mercaptobenzofurazan
- 4-Acetamido-7-mercapto-2,1,3-benzoxadiazole
Documents de produit:
Taille | Prix unitaire | Belgique | Japon * | Quantité |
---|---|---|---|---|
100MG |
€153.00
|
1 | ≥100 |
|
*Le délai de livraison pour des produits disponibles en stock en Belgique est 1 à 2 jours
*Le délai de livraison pour des produits disponibles en stock en Japon est 1 à 2 semaines (sauf des produits réglementés et des envois avec de la glace carbonique)
Numéro de produit | A5576 |
Pureté / Méthode d'analyse | >95.0%(HPLC) |
Formule moléculaire / poids moléculaire | C__8H__7N__3O__2S = 209.22 |
Etat physique (20 ° C) | Solid |
Condition de stockage | Refrigerated (0-10°C) |
Stocker sous gaz inerte | Store under inert gas |
Condition à éviter | Air Sensitive,Heat Sensitive |
Emballage Et Conteneur | 100MG-Glass Bottle with Plastic Insert (Voir l'image) |
CAS RN | 254973-02-9 |
Identifiant de la substance PubChem | 87563193 |
Numéro MDL | MFCD04038408 |
Spécifications
Appearance | Light yellow to Brown powder to crystal |
Purity(HPLC) | min. 95.0 area% |
Effect test of HPLC derivatization | Effective as labeling agent for Caproic Acid, Lauric Acid, Myristic Acid, Palmitic Acid |
Propriétés
SGH
Lois connexes:
Informations de transport:
N ° SH (import / export) (TCI-E) | 2934999090 |
Application
HPLC Labeling Reagent for Carboxylic Acids
The compound 1, an HPLC fluorescence labeling reagent, which has a 2,1,3-benzoxadiazole skeleton and a mercapto group, easily reacts with a carboxyl group to form the corresponding thioester. 1 itself fluoresces very little, but the thioester derivatives fluoresce highly. The resultant thioester is stable enough to reach the detector without any decomposition under reversed phase HPLC. An excellent chromatogram can be obtained by fluorescence detection at the excitation and emission wavelengths of 368 nm and 524 nm, respectively. [The detection limit = 10~20 fmol (S/N = 3)]
Application example:
Add 20 µL of mixed fatty acid / acetonitrile solution, 20 µL of 20 mM labeling reagent 1 / dichloromethane solution, 20 µL of triphenylphosphine / acetonitrile solution and 20 µL of 2,2’-dipyridyl disulfide / acetonitrile solution to a 500 µL vessel, and the mixture is left at room temperature for 15 min. Dilute this reactant mixture with 20 µL of acetonitrile, and use 1 µL of this diluted solution as an HPLC sample solution.
Add 20 µL of mixed fatty acid / acetonitrile solution, 20 µL of 20 mM labeling reagent 1 / dichloromethane solution, 20 µL of triphenylphosphine / acetonitrile solution and 20 µL of 2,2’-dipyridyl disulfide / acetonitrile solution to a 500 µL vessel, and the mixture is left at room temperature for 15 min. Dilute this reactant mixture with 20 µL of acetonitrile, and use 1 µL of this diluted solution as an HPLC sample solution.
TCI Products Pamphlet
HPLC Labeling Reagents ( PDF 10MB )
HPLC Labeling Reagents ( PDF 10MB )
References
PubMed Litterature
Articles / Brochures
TCIMail
Documents de produit (Note : Pour certains produits, les tableaux analytiques ne sont pas disponibles.)
Fiche de sécurité (FDS)
S'il vous plaît sélectionnez la langue.
La FDS demandée n'est pas disponible.
Nous contacter pour plus d'informations.
Spécifications
CoA et autres Certificats
Veuillez remplir le numéro de lot
Le numéro de lot saisi est incorrect. Veuillez saisir uniquement 4-5 caractères alphanumériques avant le trait d'union.
Exemple de CoA
Il s'agit d'un échantillon CoA qui peut ne pas représenter un lot récemment fabriqué du produit.
Un échantillon CoA pour ce produit n'est pas disponible pour le moment.
Graphiques analytiques
Veuillez remplir le numéro de lot
Le numéro de lot saisi est incorrect. Veuillez saisir uniquement 4-5 caractères alphanumériques avant le trait d'union.
Le tableau analytique demandé n'est pas disponible. Nous sommes désolés pour ce désagrément.