Published TCIMAIL newest issue No.197
Maximum quantity allowed is 999
Bitte wählen Sie die Menge aus.
CAS RN: 127783-34-0 | Produkte #: E0467
Ethynyl(phenyl)iodonium Tetrafluoroborate [Ethynylating Reagent]
![Ethynyl(phenyl)iodonium Tetrafluoroborate [Ethynylating Reagent] No-Image](/medias/E0467.jpg?context=bWFzdGVyfHJvb3R8NDc1MDF8aW1hZ2UvanBlZ3xhRGhtTDJnMU1pODRPVEl4TlRVNE1UVTFNamswTDBVd05EWTNMbXB3Wnd8ZWNlOWFhZmY5NTExY2M4ZTNmMmZkNTVjYWM3MDEwNjBkMmE4NWZkOTM1MTBmZjE1OGVlZTFhYTA2NmZhZmY0MA)
Reinheit: >97.0%(T)
Synonyme
Produktdokumente:
Einheit | Stückpreis | Belgien | Japan* | Menge |
---|---|---|---|---|
1G |
€355.00
|
1 | 10 |
|
*In Belgien verfügbare Lagerbestände werden in 1 bis 3 Tagen geliefert.
*In Japan verfügbare Lagerbestände werden in 1 bis 2 Wochen geliefert. (unter Ausschluss von regulierten Artikeln und Trockeneislieferungen).
Artikel # | E0467 |
Reinheit / Analysenmethode | >97.0%(T) |
Summenformel / Molekülmasse | C__8H__6BF__4I = 315.84 |
Physikalischer Zustand (20 °C) | Solid |
Lagerungstemperatur | Frozen (<0°C) |
Zu vermeidende Bedingungen | Heat Sensitive |
CAS RN | 127783-34-0 |
Reaxys Registrierungsnummer | 3578342 |
PubChem-Stoff-ID | 87569719 |
MDL-Nummer | MFCD00191648 |
Spezifikation
Appearance | White to Yellow to Orange powder to crystal |
Purity( Potassium iodate Method) | min. 97.0 % |
Eigenschaften
GHS
Piktogramm |
![]() ![]() |
Signalwort | Gefahr |
Gefahrenhinweise | H302 : Gesundheitsschädlich bei Verschlucken. H314 : Verursacht schwere Verätzungen der Haut und schwere Augenschäden. |
Sicherheitshinweise | P260 : Staub nicht einatmen. P280 : Schutzhandschuhe/ Schutzkleidung/ Augenschutz/ Gesichtsschutz/ Gehörschutz Tragen. P303 + P361 + P353 : BEI BERÜHRUNG MIT DER HAUT (oder dem Haar): Alle kontaminierten Kleidungsstücke sofort ausziehen. Haut mit Wasser abwaschen. P301 + P330 + P331 : BEI VERSCHLUCKEN: Mund ausspülen. KEIN Erbrechen herbeiführen. P304 + P340 + P310 : BEI EINATMEN: Die Person an die frische Luft bringen und für ungehinderte Atmung sorgen. Sofort GIFTINFORMATIONSZENTRUM/Arzt anrufen. P305 + P351 + P338 + P310 : BEI KONTAKT MIT DEN AUGEN: Einige Minuten lang behutsam mit Wasser spülen. Eventuell vorhandene Kontaktlinsen nach Möglichkeit entfernen. Weiter spülen. Sofort GIFTINFORMATIONSZENTRUM/Arzt anrufen. |
Verwandte Gesetze:
Transportinformationen:
UN-Nummer | UN1759 |
Klasse | 8 |
Verpackungsgruppe (DOT-AIR) | III |
HS-Nr. (Import / Export) (TCI-E) | 2942000090 |
Anwendung
Ethynylation of 1,3-Dicarbonyl Compounds
Typical Procedure:
A solution of 1,3-dicarbonyl compound (76 mg, 0.40 mmol) and NaH (11 mg, 0.48 mmol) in THF (2 mL) is stirred at rt for 1 h under an atmosphere of nitrogen. Ethynyl(phenyl)iodonium tetrafluoroborate1) (150 mg, 0.48 mmol) is then added and the resulting mixture is stirred at rt for 3 h. The reaction mixture is diluted with H2O (5 mL) and extracted with Et2O (3 x 10 mL). The combined organic layers are dried over MgSO4 and the solvent is removed under reduced pressure. The crude product is purified by silica gel flash chromatography (Hexane : EtOAc = 20 : 1) to afford the ethynylated compound (59 mg, 69%) as yellow solid.
A solution of 1,3-dicarbonyl compound (76 mg, 0.40 mmol) and NaH (11 mg, 0.48 mmol) in THF (2 mL) is stirred at rt for 1 h under an atmosphere of nitrogen. Ethynyl(phenyl)iodonium tetrafluoroborate1) (150 mg, 0.48 mmol) is then added and the resulting mixture is stirred at rt for 3 h. The reaction mixture is diluted with H2O (5 mL) and extracted with Et2O (3 x 10 mL). The combined organic layers are dried over MgSO4 and the solvent is removed under reduced pressure. The crude product is purified by silica gel flash chromatography (Hexane : EtOAc = 20 : 1) to afford the ethynylated compound (59 mg, 69%) as yellow solid.
References
- 1)Synthesis of ethynyl(phenyl)iodonium tetrafluoroborate. A new reagent for ethynylation of 1,3-dicarbonyl compounds
- 2)Ethynyl-1,2-benziodoxol-3(1H)-one (EBX): An Exceptional Reagent for the Ethynylation of Keto, Cyano, and Nitro Esters
PubMed Literatur
Artikel / Broschüren
TCIMail
Produktdokumente (Hinweis: Für einige Produkte sind keine Analysediagramme verfügbar.)
Sicherheitsdatenblatt (SDB)
Bitte wählen Sie Sprache.
Das angeforderte SDB ist nicht verfügbar.
Bitte Kontaktieren Sie uns für mehr Informationen.
Spezifikationsdokumenten
AZ & andere Zertifikate
Bitte geben Sie die Lotnummer ein
Falsche Chargennummer wurde eingegeben. Bitte geben Sie nur 4-5 alphanumerische Zeichen vor dem Bindestrich ein.
Muster-AZ
Dies ist ein Muster-AZ und repräsentiert möglicherweise nicht eine kürzlich hergestellte Charge des Produkts.
Ein Muster-AZ für dieses Produkt ist zur Zeit nicht verfügbar.
Analytische Diagramme
Bitte geben Sie die Lotnummer ein
Falsche Chargennummer wurde eingegeben. Bitte geben Sie nur 4-5 alphanumerische Zeichen vor dem Bindestrich ein.
Das angeforderte Analysediagramm ist nicht verfügbar. Wir entschuldigen uns für die Unannehmlichkeiten.