CAS RN: 19999-87-2 | Product Number: B3534

Bis(tricyclohexylphosphine)nickel(II) Dichloride


Purity: >95.0%(T)
Synonyms:
  • Dichlorobis(tricyclohexylphosphine)nickel(II)
Product Documents:
1G
$39.00
2   1   ≥40 
5G
$135.00
1   4   16  

* Items in stock locally ship in 1-2 business days. Items from Japan stock are able to ship from a US warehouse within 2 weeks. Please contact TCI for lead times on items not in stock. Excludes regulated items and items that ship on ice.
* To send your quote request for bulk quantities, please click on the "Request Quote" button. Please note that we cannot offer bulk quantities for some products.
*TCI frequently reviews storage conditions to optimize them. Please note that the latest information on the storage temperature for the products is described on our website.


Product Number B3534
Purity / Analysis Method >95.0%(T)
Molecular Formula / Molecular Weight C__3__6H__6__6Cl__2NiP__2 = 690.46 
Physical State (20 deg.C) Solid
Storage Temperature Room Temperature (Recommended in a cool and dark place, <15°C)
Packaging and Container 1G-Glass Bottle with Plastic Insert (View image)
CAS RN 19999-87-2
Reaxys Registry Number 4935620
PubChem Substance ID 125307309
MDL Number

MFCD11973802

Specifications
Appearance Yellow to Amber to Dark red powder to crystal
Purity(Chelometric Titration) min. 95.0 %
Properties (reference)
Melting Point 227 °C
GHS
Pictogram Pictogram Pictogram
Signal Word Danger
Hazard Statements H302 : Harmful if swallowed.
H372 : Causes damage to organs through prolonged or repeated exposure.
H317 : May cause an allergic skin reaction.
H334 : May cause allergy or asthma symptoms or breathing difficulties if inhaled.
H350 : May cause cancer.
Precautionary Statements P501 : Dispose of contents/ container to an approved waste disposal plant.
P260 : Do not breathe dust/ fume/ gas/ mist/ vapors/ spray.
P270 : Do not eat, drink or smoke when using this product.
P202 : Do not handle until all safety precautions have been read and understood.
P285 : In case of inadequate ventilation wear respiratory protection.
P201 : Obtain special instructions before use.
P264 : Wash skin thoroughly after handling.
P280 : Wear protective gloves/ protective clothing/ eye protection/ face protection.
P272 : Contaminated work clothing must not be allowed out of the workplace.
P308 + P313 : IF exposed or concerned: Get medical advice/ attention.
P304 + P341 : IF INHALED: If breathing is difficult, remove person to fresh air and keep comfortable for breathing.
P302 + P352 : IF ON SKIN: Wash with plenty of soap and water.
P333 + P313 : If skin irritation or rash occurs: Get medical advice/ attention.
P363 : Wash contaminated clothing before reuse.
P301 + P312 + P330 : IF SWALLOWED: Call a POISON CENTER/doctor if you feel unwell. Rinse mouth.
P405 : Store locked up.
Related Laws:
Transport Information:
HS Number 2931.90.9052
Application
Nickel Complexes for the Cross-Coupling Reactions Using Alkoxy Groups as Leaving Groups

References


Application
Nickel-Catalyzed Cross-Coupling of Aryltrimethylammonium Iodides with Organozinc Reagents

Typical procedure (Ar = Ph, R = 4-CH3Ph): Trimethylphenylammonium iodide (132 mg), bis(tricyclohexylphosphine)nickel(II) dichloride (6.9 mg) and NMP (1.5 mL) are added to a Schlenk tube. To the stirring mixture, 4-CH3C6H4ZnCl solution (1.5 mL, 1.5M solution in THF) is added by a syringe. The reaction mixture is stirred at 90 °C for 8 h and then cooled to room temperature. Water (10 mL) and several drops of acetic acid are successively added. The resulting mixture is extracted with diethyl ether (3 x 10 mL) and the extract is dried over Na2SO4, filtered and concentrated. The residue is purified by column chromatography on silica gel (eluent: petroleum ether or petroleum ether/ethyl acetate 60:1) to give 4-methylbiphenyl (76.5 mg, 91 %).

References


PubMed Literature


Product Documents (Note: Some products will not have analytical charts available.)
Safety Data Sheet (SDS)
Please select Language.

The requested SDS is not available.

Please Contact Us for more information.

Specifications
C of A & Other Certificates
Please enter Lot Number Incorrect Lot Number. Please input only the 4-5 alphanumeric characters before the hyphen.

The product with the lot number searched for has been discontinued and no related documentation is available.

Sample C of A
This is a sample C of A and may not represent a recently manufactured lot of the product.

A sample C of A for this product is not available at this time.

Analytical Charts
Please enter Lot Number Incorrect Lot Number. Please input only the 4-5 alphanumeric characters before the hyphen.

The requested analytical chart is not available. Sorry for the inconvenience.

The product with the lot number searched for has been discontinued and no related documentation is available.

Other Documents

Session Status
Your session will timeout in 10 minutes. You will be redirected to the HOME page after session timeout. Please click the button to continue session from the same page. minute. You will be redirected to the HOME page after session timeout. Please click the button to continue session from the same page.

Your session has timed out. You will be redirected to the HOME page.