CAS RN: 99-33-2 | Producten #: A5511

3,5-Dinitrobenzoyl Chloride [for HPLC Labeling]


Zuiverheid: >99.0%(T)
Synoniemen
Productdocumenten:
5G
€ 54,00
8   ≥40 

*Stock beschikbaar uit voorraad in België leverbaar in 1 tot 3 dagen
*stock beschikbaar uit voorraad in Japan leverbaar in 1 tot 2 weken (met uitzondering van gereguleerde producten en zendingen met droog ijs)


Artikel # A5511
Zuiverheid / Analysemethode >99.0%(T)
Moleculaire formule / molecuulgewicht C__7H__3ClN__2O__5 = 230.56 
Fysieke toestand (20 graden C) Solid
Opslag condities Room Temperature (Recommended in a cool and dark place, <15°C)
Opslaan onder inert gas Store under inert gas
Te vermijden condities Moisture Sensitive
CAS RN 99-33-2
Reaxys registratienummer 990249
PubChem product ID 87563158
SDBS 3430
Merck-index (14) 3277
MDL-nummer

MFCD00007248

Specificatie
Appearance White to Orange to Green powder to crystal
Purity(Argentometric Titration) min. 99.0 %
Melting point 68.0 to 71.0 °C
Solubility in Toluene almost transparency
Effect test of HPLC derivatization Effective as labeling agent for 1-Butanol
NMR confirm to structure
eigenschappen
Smeltpunt 70 °C
Kookpunt 201 °C/17 mmHg
Oplosbaarheid (oplosbaar in) Toluene, Benzene
GHS
Pictogram Pictogram Pictogram Pictogram
Signaalwoord Gevaar
Gevarenaanduidingen H302 + H312 + H332 : Schadelijk bij inslikken, bij contact met de huid en bij inademing.
H314 : Veroorzaakt ernstige brandwonden en oogletsel.
H341 : Verdacht van het veroorzaken van genetische schade.
H290 : Kan bijtend zijn voor metalen.
Voorzorgsmaatregelen P260 : Stof niet inademen.
P201 : Alvorens te gebruiken de speciale aanwijzingen raadplegen.
P280 : Draag veiligheidshandschoenen/beschermende kleding/ veiligheidsbril/ gezichtsbescherming/ gehoorbeschermers.
P303 + P361 + P353 : BIJ CONTACT MET DE HUID (of het haar): verontreinigde kleding onmiddellijk uittrekken. Huid met water afspoelen.
P304 + P340 + P310 : NA INADEMING: de persoon in de frisse lucht brengen en ervoor zorgen dat deze gemakkelijk kan ademen. Onmiddellijk een ANTIGIFCENTRUM/arts raadplegen.
P305 + P351 + P338 + P310 : BIJ CONTACT MET DE OGEN: voorzichtig afspoelen met water gedurende een aantal minuten; contactlenzen verwijderen, indien mogelijk; blijven spoelen. Onmiddellijk een ANTIGIFCENTRUM/arts raadplegen.
Gerelateerde wetten:
EC-nummers 202-750-6
RTECS # DM6637000
Transport informatie:
UN-nummer UN3261
Klasse 8
Verpakkingsgroep (DOT-AIR) III
HS-NR (invoer / uitvoer) (TCI-E) 2916399090
Toepassing
HPLC Labeling Reagent for Alcohols and Amines

The compound 1 is an HPLC labeling reagent, which easily reacts with a hydroxyl group or an amino group to form the corresponding ester or amide, respectively. The resultant ester or amide is stable and can reach the detector without any decomposition under reversed phase HPLC. An excellent chromatogram can be obtained by measuring at 254 nm, an absorption wavelength that is generally used for UV detection.

Application examples:
[Alcohols] 1)
Dissolve 1~5 mg of a sample in 5 mL of THF, and add 40 mg of the labeling reagent 1 and a few drops of pyridine. Close the cap of the reaction vessel and incubate the solution at 60 °C for 1 h. Cool the resultant solution to room temperature and use it as an HPLC sample.
Clean up before injection is recommended when pyridine or triethylamine is added to trap generated HCl. Generally, evaporate the solvent, extract with ether and wash the ether layer with diluted hydrochloric acid and water.
[Others]
Analysis of mono- and diethylene glycols in polyethylene glycol2), aliphatic alcohols3)

References


PubMed Literatuur


Artikelen / Brochures

TCIMail
Productdocumenten (Opmerking: Voor sommige producten zijn geen analytische grafieken beschikbaar.)
Veiligheidsinformatie-blad (VIB)
Selecteer alstublieft taal.

Het gevraagde SDS is niet beschikbaar.

Neem contact met ons op voor meer informatie.

Specificatiedocument
Analyse certificaat & andere certificaten
Gelieve het lotnummer in te vullen aub Er is een onjuist lotummer ingevoerd. Voer alleen 4-5 alfanumerieke tekens vóór het koppelteken in.

Het product met het gezochte lotnummer is niet meer leverbaar en er is geen bijbehorende documentatie beschikbaar.

Voorbeeldanalysecertificaat
Dit is een voorbeeldanalysecertificaat en vertegenwoordigt mogelijk niet een recent geproduceerde partij van het product.

Een voorbeeldanalysecertificaat voor dit product is op dit moment niet beschikbaar.

Analytische grafieken
Gelieve het lotnummer in te vullen aub Er is een onjuist lotummer ingevoerd. Voer alleen 4-5 alfanumerieke tekens vóór het koppelteken in.

De gevraagde analytische grafiek is niet beschikbaar. Onze excuses voor het ongemak.

Het product met het gezochte lotnummer is niet meer leverbaar en er is geen bijbehorende documentatie beschikbaar.

Andere documenten

Sessiestatus
Uw sessie verloopt over 10 minuten. Na het verlopen van de sessie word u doorgestuurd naar de startpagina. Klik op de knop om de sessie vanaf dezelfde pagina voort te zetten. minuut. Na het verlopen van de sessie word u doorgestuurd naar de startpagina. Klik op de knop om de sessie vanaf dezelfde pagina voort te zetten.

Uw sessie is verlopen. U wordt doorgestuurd naar de startpagina.