Maintenance Notice (4:30 AM - 11:00 AM December 21, 2024): This website is scheduled to be unavailable due to maintenance. We appreciate your patience and understanding.
Published TCIMAIL newest issue No.197
Maximum quantity allowed is 999
Taille | Prix unitaire | Belgique | Japon * | Quantité |
---|---|---|---|---|
10G |
€27.00
|
2 | ≥100 |
|
25G |
€39.00
|
14 | ≥100 |
|
250G |
€273.00
|
2 | 23 |
|
*Le délai de livraison pour des produits disponibles en stock en Belgique est 1 à 2 jours
*Le délai de livraison pour des produits disponibles en stock en Japon est 1 à 2 semaines (sauf des produits réglementés et des envois avec de la glace carbonique)
Numéro de produit | I0330 |
Pureté / Méthode d'analyse | >97.0%(T) |
Formule moléculaire / poids moléculaire | C__1__0H__1__1IO__4 = 322.10 |
Etat physique (20 ° C) | Solid |
Condition de stockage | Room Temperature (Recommended in a cool and dark place, <15°C) |
Stocker sous gaz inerte | Store under inert gas |
Condition à éviter | Moisture Sensitive |
CAS RN | 3240-34-4 |
Numéro de registre de Reaxys | 1879369 |
Identifiant de la substance PubChem | 87571686 |
SDBS | 12662 |
Numéro MDL | MFCD00008692 |
Appearance | White to Light yellow powder to crystal |
Purity(Iodometric Titration) | min. 97.0 % |
Solubility in Methanol | almost transparency |
Point de fusion | 158 °C(dec.) |
solubilité dans l'eau | Insoluble |
Solubilité (soluble dans) | Methanol |
Solubilité (insoluble dans) | Ether |
Pictogramme | |
Mot de signal | Attention |
Mentions de danger | H315 : Provoque une irritation cutanée. H319 : Provoque une sévère irritation des yeux. |
Conseils de prudence | P264 : Se laver la peau soigneusement après manipulation. P280 : Porter des gants de protection/ un équipement de protection des yeux/ du visage. P302 + P352 : EN CAS DE CONTACT AVEC LA PEAU: Laver abondamment à l’eau. P337 + P313 : Si l'irritation oculaire persiste: consulter un médecin. P362 + P364 : Enlever les vêtements contaminés et les laver avant réutilisation. P332 + P313 : En cas d'irritation cutanée: consulter un médecin. |
Numéros CE | 221-808-1 |
RTECS # | DA3525000 |
N ° SH (import / export) (TCI-E) | 2931900090 |
To a solution of 1-naphthalenemethanol (306 mg, 2.0 mmol) in dichloromethane (2 mL, 1.0 mol/L) was added TEMPO (31.2 mg, 0.20 mmol), PhI(OAc)2 (709mg, 2.2 mmol) and the mixture was stirred at room temperature for 4 hours. Dichloromethane (12.5 mL), saturated aqueous sodium thiosulfate solution (12.5 mL) was added and the mixture was stirred for 30 minutes. The organic layer was washed with saturated aqueous sodium bicarbonate solution (10 mL), brine (10 mL) and the organic layer was dried over sodium sulfate and filtered. The solvent was removed under reduced pressure and the residue was purified by column chromatography (ethyl acetate:hexane = 0:100 - 3:97 on silica gel) to give 1-naphthaldehyde as a yellow liquid (291 mg, 93%).
The reaction mixture was monitored by TLC (ethyl acetate:hexane = 1:9, Rf = 0.50).
1-Naphthaldehyde
1H NMR (400 MHz, CDCl3); δ 10.41 (s, 1H), 9.26 (d, J = 8.9 Hz, 1H), 8.11 (d, J = 8.4 Hz, 1H), 8.01 (d, J = 6.8 Hz, 1H), 7.93 (d, J = 8.9 Hz, 1H), 7.74-7.57 (m, 3H).
To a solution of 2-phenylimidazoline (500 mg, 3.4 mmol), potassium carbonate (520 mg, 3.8 mmol, 1.1 equiv) in DMSO (17 mL) was added iodobenzene diacetate (1.21 g, 3.8 mmol, 1.1 equiv) and stirred at rt for 18 hours. The residue was diluted with ethyl acetate (75 mL) and washed with saturated aqueous sodium bicarbonate solution (50 mL, twice) dried over sodium sulfate and filtered. The solvent was removed under reduced pressure and the residue was purified by column chromatography (on aminosilica gel, ethyl acetate:hexane = 0:1 - 1:0), giving 2-phenylimidazole as a white solid (340 mg,y. 69%).
The reaction mixture was monitored by NH-TLC (ethyl acetate, Rf = 0.30).
2-phenylimidazole
1H NMR (270 MHz, DMSO-d6); δ 12.5 (dr, 1H), 7.95-7.91 (m, 2H), 7.44 (t, 2H, J = 7.3 Hz), 7.33 (t, 1H, J = 7.3 Hz), 7.24 (s, 1H), 7.02 (s, 1H)
La FDS demandée n'est pas disponible.
Nous contacter pour plus d'informations.
Un échantillon CoA pour ce produit n'est pas disponible pour le moment.
Le tableau analytique demandé n'est pas disponible. Nous sommes désolés pour ce désagrément.