Published TCIMAIL newest issue No.197
Maximum quantity allowed is 999
Merci de sélectionner la quantité
CAS RN: 98358-90-8 | Numéro de produit: A5595
DBD-F [=4-(N,N-Dimethylaminosulfonyl)-7-fluoro-2,1,3-benzoxadiazole] [for HPLC Labeling]
![DBD-F [=4-(N,N-Dimethylaminosulfonyl)-7-fluoro-2,1,3-benzoxadiazole] [for HPLC Labeling] No-Image](/medias/A5595.jpg?context=bWFzdGVyfHJvb3R8NTY1MTV8aW1hZ2UvanBlZ3xhRGhsTDJoa09DODRPVEU1TnpReU5ERTBPRGM0TDBFMU5UazFMbXB3Wnd8ZmE5MTJjNTAyNzJlZjI5NjZkNjkzMGU1MzZhNmQ0OTg2NTRkNTIzMDJiZWY5OGJiNjE5NDU3NWVkNDNlMTRkMA)
Pureté: >98.0%(HPLC)
Synonymes
- 4-(N,N-Dimethylaminosulfonyl)-7-fluoro-2,1,3-benzoxadiazole
- 7-Fluoro-4-(N,N-dimethylaminosulfonyl)benzofurazan
- 7-Fluoro-4-(N,N-dimethylsulfamoyl)-2,1,3-benzoxadiazole
Documents de produit:
Taille | Prix unitaire | Belgique | Japon * | Quantité |
---|---|---|---|---|
100MG |
€144.00
|
Contactez-nous | ≥100 |
|
*Le délai de livraison pour des produits disponibles en stock en Belgique est 1 à 2 jours
*Le délai de livraison pour des produits disponibles en stock en Japon est 1 à 2 semaines (sauf des produits réglementés et des envois avec de la glace carbonique)
Numéro de produit | A5595 |
Pureté / Méthode d'analyse | >98.0%(HPLC) |
Formule moléculaire / poids moléculaire | C__8H__8FN__3O__3S = 245.23 |
Etat physique (20 ° C) | Solid |
Condition de stockage | Refrigerated (0-10°C) |
Condition à éviter | Light Sensitive,Heat Sensitive |
CAS RN | 98358-90-8 |
Numéro de registre de Reaxys | 8142578 |
Identifiant de la substance PubChem | 87563202 |
Numéro MDL | MFCD00143356 |
Spécifications
Appearance | White to Light yellow to Light orange powder to crystal |
Purity(HPLC) | min. 98.0 area% |
Melting point | 124.0 to 128.0 °C |
Effect test of HPLC derivatization | Effective as labeling agent for L-Valine. |
Propriétés
Point de fusion | 128 °C |
SGH
Pictogramme |
![]() |
Mot de signal | Attention |
Mentions de danger | H315 : Provoque une irritation cutanée. H319 : Provoque une sévère irritation des yeux. |
Conseils de prudence | P264 : Se laver la peau soigneusement après manipulation. P280 : Porter des gants de protection/ un équipement de protection des yeux/ du visage. P302 + P352 : EN CAS DE CONTACT AVEC LA PEAU: Laver abondamment à l’eau. P337 + P313 : Si l'irritation oculaire persiste: consulter un médecin. P362 + P364 : Enlever les vêtements contaminés et les laver avant réutilisation. P332 + P313 : En cas d'irritation cutanée: consulter un médecin. |
Lois connexes:
Informations de transport:
N ° SH (import / export) (TCI-E) | 2935909099 |
Application
HPLC Labeling Reagent for Amines and Thiols
The compound 1 which is an HPLC fluorescence labeling reagent having a 2,1,3-benzoxadiazole skeleton, can easily react with amino and mercapto groups to form the corresponding derivatives. The derivatives are stable enough to reach the detector without any decomposition under reversed phase HPLC. An excellent chromatogram can be obtained by fluorescence detection at the excitation and emission wavelengths of 450 nm and 590 nm, respectively.
Application example:
[Amino acids]
0.5 mL of 20 mM labeling reagent in acetonitrile is put into an amber-glass vial. To this solution, add 0.5 mL of 0.1 M boric acid buffer solution (pH 9.3, containing 1mM EDTANa2) containing several nmol of an amino acid, and incubate at 50 °C for 30 min. After cooling the reaction mixture with ice bath, use it as an HPLC sample.
For example, the detection limit (S/N=3) for proline is 0.11 pmol.
[Amino acids]
0.5 mL of 20 mM labeling reagent in acetonitrile is put into an amber-glass vial. To this solution, add 0.5 mL of 0.1 M boric acid buffer solution (pH 9.3, containing 1mM EDTANa2) containing several nmol of an amino acid, and incubate at 50 °C for 30 min. After cooling the reaction mixture with ice bath, use it as an HPLC sample.
For example, the detection limit (S/N=3) for proline is 0.11 pmol.
TCI Products Pamphlet
HPLC Labeling Reagents ( PDF 10MB )
HPLC Labeling Reagents ( PDF 10MB )
References
- 1)T. Toyo’oka, T. Suzuki, Y. Saito, S. Uzu, K. Imai, Analyst 1989, 114, 413.
- 2)T. Toyo’oka, T. Suzuki, Y. Saito, S. Uzu, K. Imai, Analyst 1989, 114, 1233.
- 3)K. Imai, S. Uzu, T. Toyo’oka, J. Pharm. Biomed. Anal. 1989, 7, 1395.
- 4)S. Uzu, K. Imai, K. Nakashima, S. Akiyama, Analyst 1991, 116, 1353.
- 5)S. Uzu, K. Imai, K. Nakashima, S. Akiyama, Biomed. Chromatogr. 1991, 5, 184.
PubMed Litterature
Articles / Brochures
TCIMail
Documents de produit (Note : Pour certains produits, les tableaux analytiques ne sont pas disponibles.)
Fiche de sécurité (FDS)
S'il vous plaît sélectionnez la langue.
La FDS demandée n'est pas disponible.
Nous contacter pour plus d'informations.
Spécifications
CoA et autres Certificats
Veuillez remplir le numéro de lot
Le numéro de lot saisi est incorrect. Veuillez saisir uniquement 4-5 caractères alphanumériques avant le trait d'union.
Exemple de CoA
Il s'agit d'un échantillon CoA qui peut ne pas représenter un lot récemment fabriqué du produit.
Un échantillon CoA pour ce produit n'est pas disponible pour le moment.
Graphiques analytiques
Veuillez remplir le numéro de lot
Le numéro de lot saisi est incorrect. Veuillez saisir uniquement 4-5 caractères alphanumériques avant le trait d'union.
Le tableau analytique demandé n'est pas disponible. Nous sommes désolés pour ce désagrément.